INSTALLATION INSTRUCTIONS

Preliminary Notes Before Installation

This appliance is an Inset Live Fuel Effect appliance that provides radiant warmth utilising the latest type
burner technology.

The fire is designed to fit various types of fireplaces and natural draught flues as listed in the Installation
Requirements.

The appliance must be installed by a competent

[1] 

person in accordance with Gas Safety (Installation and

Use) Regulations 1998. 

Read all these instructions before commencing installation.

This appliance must be installed in accordance with the rules in force and only used in a sufficiently venti-
lated space.

The appliance is designed for installation on to a non-combustible hearth of at least 300mm depth.

This appliance is factory set for operation on the gas type, and at the pressure stated on the appliance
data plate.

Eko 307

0

©

2009 Focal Point Fires plc.

[1] GB - Gas Safe

TM

registered operatives (Northern Ireland only- CORGI registered operatives) are the only class of person considered as competent by the HSE under the Gas Safety (Installation and Use)

Regulations 1998.

Please note : Except where otherwise stated, all rights, including copyright in the text, images and layout of
this booklet is owned by Focal Point Fires plc.  You are not permitted to copy or adapt any of the content
without the prior written permission of Focal Point Fires plc. 

Summary of Contents for EKO 3070

Page 1: ...installation and user instructions All instructions must be handed to user for safekeeping Revision A 06 09 Country s of destination GB IE eko 3070 fuel effect gas fire...

Page 2: ...ly used in a sufficiently venti lated space The appliance is designed for installation on to a non combustible hearth of at least 300mm depth This appliance is factory set for operation on the gas typ...

Page 3: ...fractories and coal bed are constructed from ceramic fibre 1 Section 1 0 2 0 3 0 4 0 4 1 5 0 6 0 7 0 7 1 8 0 8 1 9 0 10 0 Contents Important Notes Appliance Data Installation Requirements Site Require...

Page 4: ...e checked before installation by using a smoke pellet or similar to ensure proper draw and that leakage is not evident at any joints Repair and re test as necessary before the appliance is installed T...

Page 5: ...erly up the flue the outlet at the back of the appli ance must have a 50mm minimum clearance between it and the back wall of the opening or any other obstruction The area immediately above the outlet...

Page 6: ...BOXES This appliance can be fitted into a number of proprietary flue boxes provided that the minimum dimensions given in the diagram below are complied with Constructional Note The frame of the fire a...

Page 7: ...de panels should be fitted by inserting their front edges into the pre fitted retaining brackets on the front face of the fire box Gently align the side panels with the side of the firebox as shown ov...

Page 8: ...ectly the sealing face sits flat and square to the wall or infill panel and that the base is firm on the floor of the opening as no leaks are permissible here At this stage it is essential to ensure t...

Page 9: ...ion does not allow the exact layout given the eyebolts should be positioned as close to the correct layout as possible Before finally fitting cables ensure the self adhesive sealing strips are in posi...

Page 10: ...adjust this If under any circumstances the electric spark fails the pilot may be lit manually by proceeding with the ignition sequence as previously described and after turning the control knob throug...

Page 11: ...cleaning of the fire may be achieved when the fire is cold using a damp cloth and mild detergent on most surfaces Scratched and other superficial damage to the matt black paintwork of the appliance ca...

Page 12: ...any debris Remove the two tubing nuts on the ends of the gas pipe to the injector elbow and blow clear Release the screw through the supporting leg and lift assembly clear The injector pipe can now b...

Page 13: ...and then cuts off Excessive room draught or flue pull rectify Loose or faulty thermocouple rectify ODS system in operation Firebox grommet seal not fitted rectify Lint in pilot aeration hole clean th...

Page 14: ...ial or flooring should protrude onto the hearth DO NOT burn any foreign material on this fire the coals must be of the correct type and laid out in accor dance with the relevant section of these instr...

Page 15: ...d ventilation of at least 8 75cm2 The requirements of other appliances operating in the same space or room and the results of a spillage test must be taken into con sideration when assessing ventilati...

Page 16: ...ong the rear of the matrix Do not place the coals directly over the holes in the matrix The coals may be rotat ed as desired to ensure they sit firmly on the various supporting parts of the matrix 6 F...

Page 17: ...ught should resolve this The fire can then be re lit in accordance with the previous section A grommet seal may also be missing from the firebox causing abnormal draught to shut down the pilot Call yo...

Reviews: