19
10) If individual cell fails, identify the cause and repair the cell immediately. Replace the cell when it cannot be
repaired.
11) The site for recharging should be well ventilated. It is prohibited to smoke or use open fire, avoiding the risk of
hydrogen explosion.
12) The electrolyte in accumulator is toxic and corrosive. For this reason, always wear working suit and protection
glasses to protect your body from contacting the electrolyte in accumulator.
13) If your clothes, skin or eyes are spilled with acid liquid in accumulator, flush with large amount of clean water.
For skin and eyes, flush with large amount of clean water and also seek doctor’s treatment immediately. Acid spillage
must be neutralized and treated immediately.
14) The weight and dimensions of the accumulator have remarkable effect on stability of the stacker. Therefore do
not modify the type of accumulator without approval from the manufacturer.
15) Never discharge in large current, for example, performs travelling and lifting simultaneously.
9.4.4 Disposition of worn-out accumulators
Worn-out accumulators should be recycled according to local regulations, and stored in specified zone or cast-off
treatment zone. These works should be done by qualified specialized companies.
9.4.5 Specification of the accumulator
Battery
Charger
Rated power
:
24V
Load capacity
:
2*12V/150Ah(EB18E)
24V/210AH(EB20E)
Input
:
195/265VAC
50/60Hz
Output
:
24V/20A(EB18E)
24V30A(EB20E)
The battery's non-insulated terminal must be protected by an insulating cover. When the battery is connected and
connected to the socket, the vehicle must be cut off and the switch in the closed position. When replacing or
assembling the battery, make sure the battery is securely fixed in the battery box.
9.4.6 Storage, transportation and installation of the accumulator
The truck must be parked on the level ground steadily. To prevent short circuit, naked cable ends and the terminal
posts should be covered with insulated covers. When pulling out the accumulator, properly arrange removed
accumulator's connectors and cables without blocking access of the accumulator.
9.4.7 Battery power indicator
Battery power display table: ten article showing represent 100% of the battery. With the consumption of battery
capacity, the glowing article shows will be from top to down.
Summary of Contents for EB18E
Page 6: ...5 EB20E ...