OpErAtInG InStructIOnS

en

01

ekey home

Touchpad Operating Instructions

Summary of Contents for home FS OM

Page 1: ...www rkdoorsystems co uk OpErAtInG InStructIOnS en 01 ekey home Touchpad Operating Instructions...

Page 2: ...s and establishing normal mode 8 Entering the admin code 8 Changing the admin code 9 10 Setting the automatic back illumination 11 Setting the brightness of the back illumination 11 Setting the relay...

Page 3: ...ices are not used within the scope of proper use Unauthorised modifications are carried out on the system devices by the operator These operating instructions are not subject to updating Subject to op...

Page 4: ...to be operated with safety extra low ekey home voltage SELV Only use power supplies rated protection class 2 according to VDE 0140 1 Failure to do so will result in life threatening danger due to elec...

Page 5: ...features pin codes are entered and compared with the stored reference codes If they match up the door opens The system is primarily designed for opening house doors apartment doors and garage doors i...

Page 6: ...orrect menu item etc An acoustic signal transmitter signals that the button has been pressed and that access has been enabled The back illumination of the keypad is blue dimmable and switches on or of...

Page 7: ...g 1 relay 1 input Integration into doors 1 relay Table 3 Control panel makeups Function of the control panel The control panel is the actuator of the system It serves to switch one relay Controls and...

Page 8: ...eed s 1 after input is complete Operational lifetime Button presses approx 1 million Table 5 Technical specifications ekey home keypad integra 2 0 Description Unit Value ekey home CP mini 1 ekey home...

Page 9: ...l to light up check the wiring and power supply Implementation Implementing the devices couples the control panel and the code pad with one another The following steps apply to the only ekey home CP m...

Page 10: ...It automatically switches back to normal mode if you do not press a button within 10 s This function allows you to change the existing admin code The admin code may contain between 4 and 8 digits The...

Page 11: ...w on the left and green on the right The status LEDs light up red The required admin code has already been assigned as a user code Enter the admin code from the beginning again 7 Enter the new admin c...

Page 12: ...tatus LED lights up green on the left 2 Press The status LEDs light up green The status LEDs light up red Something has been entered incorrectly The brightness threshold was not changed Enter the admi...

Page 13: ...is in normal mode The switching time for the relay can be set up to 99 9 in 0 1 second increments By default the switching time is set to 3 seconds Enter the required relay switching time in tenths o...

Page 14: ...nd optical signals off 1 acoustic signals on and optical signals off 2 acoustic signals off and optical signals on 3 acoustic and optical signals on The signalling to indicate that a button has been p...

Page 15: ...green on the left 2 Press The status LEDs light up green The status LEDs light up red Something has been entered incorrectly The signalling was not changed Enter the admin code from the beginning aga...

Page 16: ...r code is already present Enter the admin code from the beginning again 4 Enter the required user code again on the keypad 5 Press The status LEDs light up green The status LEDs light up red The two e...

Page 17: ...er 3 times there will be a 15 minute lock There will be another 15 minute lock each time the code is entered incorrectly after that NOTICE You can also open the door using the digital input PIN 7 8 on...

Page 18: ...erably deleted The admin code is reset to the default setting 9999 the relay switching time to 3 seconds the brightness threshold to 10 and the brightness value to 100 The acoustic and optical signall...

Page 19: ...ntrol panel This can only be undertaken mini 1 for the 1 at the factory ekey home CP micro Step Action Description Display 1 Press and hold the button with the operating rod for at least 4 seconds Sta...

Page 20: ...e status LED lights up red on the right An incorrect user code has been entered 3 times 1 minute or 15 minute system lock After the 1 minute or 15 minute lock enter a correct user code The 1 minute or...

Page 21: ...ekey biometric systems GmbH Translated documentation 20 en Dismantling and disposal Pursuant to Directive 2002 96 EC of the European Parliament and Council of 27 January 2003 on the sale return and e...