background image

8

 Notice for this Monitor

To Use the Monitor for a Long Time

 

Quality control

 •

The display quality of monitors is affected by the quality level of input signals and the degradation of 

the product. Perform visual checks and periodic constancy tests to comply with medical standards / 
guidelines according to your application, and carry out calibration as necessary. Use of the RadiCS 

monitor quality control software enables the user to perform high-level quality control that meets 

medical standards / guidelines. For how to perform various tests and calibration, refer to the 
RadiCS User's Manual.

 • It takes about 30 minutes for the monitor display to stabilize. Please wait 30 minutes or more after 

the monitor power has been turned on or the monitor has recovered from the power saving mode 

before performing various tests for quality control, calibration, or screen adjustment of the monitor.

 • We recommend that monitors be set to the recommended level or lower to reduce changes in 

luminosity caused by long-term use and maintain stable brightness.

Attention

 • The display status of the monitor may change unexpectedly due to an operating error or unexpected setting 

change. Using the monitor with the control buttons locked is recommended after adjusting the screen of the 
monitor. For details on how to set, refer to the Installation Manual (on the CD-ROM).

 

Cleaning

Periodic cleaning is recommended to keep the monitor looking new and to prolong its operation 
lifetime.
Carefully wipe the cabinet and panel surface with a soft cloth moistened with water or the following 
chemicals. 

Chemicals that may be used for cleaning 

Material name

Product name

Ethanol for disinfection

Ethyl alcohol (Ethanol)

Isopropyl alcohol

Isopropyl alcohol

Chlorhexidine gluconate

Hibitane solution

Sodium hypochlorite

Purelox

Benzalkonium chloride

Welpas

Alkyldiamino ethylglycine

Tego 51

Glutaral

Cidexplus 28

Attention

 •

Do not use chemicals frequently. Chemicals such as alcohol and antiseptic solution may cause gloss 
variation, tarnishing, and fading of the cabinet or panel, and also quality deterioration of the image.

 • Never use any thinner, benzene, wax, and abrasive cleaner, which may damage the cabinet or panel.
 • Do not attach chemicals directly to the monitor.

Note

 • Using ScreenCleaner (optional) for cleaning of the cabinet and the panel surface is recommend.

To Use the Monitor Comfortably

 •Staring at the monitor for a long time tires your eyes. Take a 10-minute rest every hour.
 •Look at the screen from a proper distance and from a proper angle.

Summary of Contents for RadiForce MX194

Page 1: ...urself with safe and effective usage Please retain this manual for future reference For monitor adjustment and settings refer to the Installation Manual For the latest product information including th...

Page 2: ...unit This product has been adjusted specifically for use in the region to which it was originally shipped If operated outside this region the product may not perform as stated in the specifications N...

Page 3: ...n of the Caution Statements Symbols on the unit Symbol This symbol indicates Power button Press to turn the monitor s power on or off Alternating current Alerting electrical hazard CAUTION Refer to SA...

Page 4: ...not place in any form of transportation ships aircraft trains automobiles etc Do not place in dusty or humid environments Do not place in locations where water may be splashed on the screen bathrooms...

Page 5: ...and install the unit securely Otherwise the unit may become detached resulting in injury and or equipment damage Before installation make sure that desks walls or any other installation surface has a...

Page 6: ...tall the unit in a place with poor ventilation or inadequate space Do not use the unit laid down or upside down Blocking the ventilation slots prevents proper airflow and may result in fire electric s...

Page 7: ...even after a short time period has elapsed depending on the displayed image If this occurs changing the image or leaving the power off for a few hours may solve the problem The backlight of the LCD p...

Page 8: ...ng change Using the monitor with the control buttons locked is recommended after adjusting the screen of the monitor For details on how to set refer to the Installation Manual on the CD ROM Cleaning P...

Page 9: ...and Functions 11 Chapter 2 Installation Connection 12 2 1 Before Installing the Product 12 Installation Requirements 12 2 2 Connecting Cables 13 2 3 Turning On the Power 14 2 4 Adjusting the Screen He...

Page 10: ...l position for easy operation and minimizing fatigue Tilt 30 up 0 down swivel 35 right 35 left adjustable height 100 mm 1 2 Package Contents Check that all of the following items are included in the p...

Page 11: ...e operation guide and the menus refer to the Installation Manual on the CD ROM 3 button Turns the power on or off 4 Power Indicator Indicates the monitor s operation status Green Operating Orange Powe...

Page 12: ...this product on a lacquer coated desk the color may adhere to the bottom of the stand due to the composition of the rubber Check the desk surface before use Installation Requirements When installing t...

Page 13: ...ns page 17 before connecting the PC 1 Connect signal cables Check the shapes of the connectors and connect the cables After connecting the DVI cable or the D Sub cable to the monitor tighten the faste...

Page 14: ...ompletely when not using the monitor Note When turning on the monitor and PC for the first time with the analog signal the Auto Adjustment function works to adjust the clock phase and display position...

Page 15: ...r reboot the PC 2 The message below appears This message appears when the signal is not input correctly even when the monitor functions properly This message appears when no signal is input Example Th...

Page 16: ...400 69 Hz 71 Hz D Sub 50 0 Hz 75 0 Hz Synchronization Signal Separate Dot Clock Max DVI DisplayPort 108 MHz D Sub 135 MHz USB Port Upstream x 1 Standard USB Specification Revision 2 0 Power Input 100...

Page 17: ...nnected and DP Power Save On 4 2 Compatible Resolutions The monitor supports the following resolutions For Digital Signal Input DisplayPort DVI Resolution Vertical Scan Frequency 640 x 480 60 Hz 720 x...

Page 18: ...or EIZO FP 702 Arm Stand EIZO LS HM1 D Dual height adjustable stand EIZO LA 011 W Wall hung arm EIZO AAH 02B3W Wall hung arm Calibration Kit EIZO RadiCS UX2 Ver 4 6 3 or later Network QC Management So...

Page 19: ...etic waves that could influence limit or result in malfunction of the monitor Install the equipment in a controlled environment where such effects are avoided Classification of Equipment Type of prote...

Page 20: ...ent or stacked use is necessary the equipment or system should be observed to verify normal operation in the configuration in which it will be used When using a portable RF communication equipment kee...

Page 21: ...idance Electrostatic discharge ESD IEC EN61000 4 2 8 kV contact discharge 15 kV air discharge 8 kV contact discharge 15 kV air discharge Floors should be wood concrete or ceramic tile If floors are co...

Page 22: ...site survey a should be less than the compliance level in each frequency range b Interference may occur in the vicinity of equipment marked with the following symbol Note 1 UT is the a c mains voltage...

Page 23: ...aximum power W Minimum separation distance m IEC EN60601 test level V m Compliance level V m 385 380 390 TETRA 400 Pulse modulation b 18 Hz 1 8 0 3 27 27 450 430 470 GMRS 460 FRS 460 FM 5 kHz deviatio...

Page 24: ...Hz to 80 MHz d 1 2 P 80 MHz to 800 MHz d 1 2 P 800 MHz to 2 7 GHz d 2 3 P 0 01 0 12 0 12 0 23 0 1 0 38 0 38 0 73 1 1 2 1 2 2 3 10 3 8 3 8 7 3 100 12 12 23 For transmitters rated at a maximum output po...

Page 25: ...ce to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television receptio...

Page 26: ...ZO Corporation All rights reserved 1st Edition March 2018 Printed in Japan 00N0N072A1 IFU MX194 6 http www eizoglobal com 153 Shimokashiwano Hakusan Ishikawa 924 8566 Japan 8 5B Siemensallee 84 76187...