3. Screen Adjustment and Settings
1
-. Off Timer
The off timer function causes the monitor to automatically enter a power off state after a predetermined
amount of time has lapsed. This function was created to reduce Afterimage characteristics that are
particular to LCD monitors when the monitor screen is left on for a long period without use.
[Procedure]
1. Select <Off Timer> in the ScreenManager <Others> menu.
2. Select "Enable" and touch the Right and Left directing switches to adjust the operating time (1 to 23
hours).
[Off Timer System]
PC
Monitor
Power Indicator
Operating time (1H - 23H)
Operation
Blue
Last 15 min. in operating time
Advance Notice
*
1
Blue Flashing
Operating time expired
Power Off
Off
*1
When
is pressed during the advance notice period, the monitor continues to operate for additional 90 minutes. Extension
of operation time can be set without limitation.
[Power Resumption Procedure]
Press
to return a normal screen.
NOTE
• The off timer function works while the PowerManager is active, but there is no advance notice before
the monitor's power is turned off.
-. Locking the Settings
Use the "Adjustment Lock" function to prevent any accidental changes.
Buttons that can be locked
•
(Enter button) / Adjustments/settings using Adjustment menu
Buttons that cannot be locked
•
(Input Signal Selection button)
•
-/$%
(Mode button)
•
(Power button)
[How to lock]
1. Press
to turn off the unit.
2. Press
again while pressing
-/$%
.
The screen is displayed with the adjustment lock.
[How to unlock]
1. Press
to turn off the unit.
2. Press
again while pressing
-/$%
.
The screen is displayed with the adjustment lock released.
NOTE
•
The adjustment lock function may activate when calibration is performed with the calibration kit. The
monitor can be unlocked using the same unlocking procedure described above.