GB
- 25 -
10. Possible causes of failure
Problem
Cause
Solution
The compressor
does not start.
1. No supply voltage.
2. Insu
ů
cient supply voltage.
3. Outside temperature is too low.
4. Motor is overheated.
1. Check the supply voltage, the pow-
er plug and the socket-outlet.
2. Make sure that the extension cable
is not too long. Use an extension
cable with large enough wires.
3. Never operate with an outside tem-
perature of below +5° C.
4. Allow the motor to cool down. If
necessary, remedy the cause of the
overheating.
The compressor
starts but there is no
pressure.
1. The non-return valve leaks.
2. The seals are damaged.
3. The drain plug for condensation
water leaks.
1. Have a service center replace the
non-return valve.
2. Check the seals and have any da-
maged seals replaced by a service
center.
3. Tighten the screw by hand. Check
the seal on the screw and replace if
necessary.
The compressor
starts, pressure is
shown on the pres-
sure gauge, but the
tools do not start.
1. The hose connections have a leak.
2. A quick-lock coupling has a leak.
3. Insu
ů
cient pressure set on the
pressure regulator.
1. Check the compressed air hose
and tools and replace if necessary.
2. Check the quick-lock coupling and
replace if necessary.
3. Increase the set pressure with the
pressure regulator.
Anl_SA_TH_AC_200_30_OF_SPK8.indb 25
07.05.15 14:13
Summary of Contents for TH-AC 200/30 OF
Page 2: ... 2 1 2 3 4 2 3 5 4 7 6 A 3 8 10 9 5 B Anl_SA_TH_AC_200_30_OF_SPK8 indb 2 07 05 15 14 13 ...
Page 3: ... 3 4 5a 5b A 3 B 6 1 3 10 Anl_SA_TH_AC_200_30_OF_SPK8 indb 3 07 05 15 14 13 ...
Page 41: ... 41 Anl_SA_TH_AC_200_30_OF_SPK8 indb 41 07 05 15 14 13 ...
Page 42: ... 42 Anl_SA_TH_AC_200_30_OF_SPK8 indb 42 07 05 15 14 13 ...
Page 43: ... 43 Anl_SA_TH_AC_200_30_OF_SPK8 indb 43 07 05 15 14 13 ...
Page 44: ...EH 05 2015 01 Anl_SA_TH_AC_200_30_OF_SPK8 indb 44 07 05 15 14 13 ...