GB
- 28 -
11. Troubleshooting
Fault
Possible causes
Remedies
The motor fails to
start
a) The capacitor is defective
b) There is no electricity at the plug
c) The cable is defective
d) The combined switch/plug is de-
fective
e) The connectors have become
separated from the motor or the
capacitor
f) The mower is standing in high
grass
g) The mower housing is clogged
a) The mower housing is clogged.
Have repaired by the Customer
Service Center
b) Check the cable and the fuse
c) Check the cable
d) Have repaired by the Customer
Service Center
e) Have repaired by the Customer
Service Center
f) Start in low grass or on an area that
has already been mowed; change
the cutting height if necessary
g) Clean the housing so that the blade
moves freely
The motor perfor-
mance drops
a) The grass is too high or too damp
b) The mower housing is clogged
c) The blade is severely worn
a) Correct the cutting height
b) Clean the housing
c) Replace the blade
Cutting is irregular
a) The blade is worn
b) Wrong cutting height
a) Replace or resharpen the blade
b) Correct the cutting height
Important! For protection, the motor is equipped with a thermal switch which cuts out when
the motor is overloaded and switches on again automatically after a short cooling period.
Anl_GC_EM_1030_SPK7.indb 28
Anl_GC_EM_1030_SPK7.indb 28
16.10.14 10:14
16.10.14 10:14
Summary of Contents for GC-EM 1030
Page 205: ... 205 Anl_GC_EM_1030_SPK7 indb 205 Anl_GC_EM_1030_SPK7 indb 205 16 10 14 10 14 16 10 14 10 14 ...
Page 206: ... 206 Anl_GC_EM_1030_SPK7 indb 206 Anl_GC_EM_1030_SPK7 indb 206 16 10 14 10 14 16 10 14 10 14 ...
Page 207: ... 207 Anl_GC_EM_1030_SPK7 indb 207 Anl_GC_EM_1030_SPK7 indb 207 16 10 14 10 14 16 10 14 10 14 ...