GB
- 3 -
The corresponding safety information / instructions can be
found in the safety information and original operating instruc-
tions issued for the equipment. Warning!
Read all the safety
information and instructions carefully!
Description
A - Button for battery charge level indicator
B - Display for battery charge level indicator
Important! According to special provision 188, the lithium-ion battery must always be set to 4 Ah (72 Wh) before
it can be shipped or transported! Faulty lithium-ion batteries must never be shipped in the ordinary mail! Ple-
ase contact iSC GmbH, Eschenstraße 6, 94405 Landau/Isar (Germany) for this.
www.isc-gmbh.info
Battery charge level indicator
Press the battery charge level indicator button (A) brie
fl
y. The display (B) for the battery charge level indicator initially dis-
plays the charge status in % and then the current set charge level consecutively for 2 seconds each.
Important!
The charge status adjusts automatically after a switch to 4 Ah or 6 Ah and can di
ff
er from the previous setting. If the battery
has a charge status of 100 % when set to 4.0 Ah, for instance, and is then switched to 6.0 Ah, the charge status will fall to
signi
fi
cantly less than 100 %. You will need to recharge the battery.
Error codes
Code
Cause
Remedy
F01
The battery is too hot (e.g. due to direct
sunlight)
Store it at room temperature (approx. 20° C) for one
day.
F02
The battery is too cold
Store it at room temperature (approx. 20° C) for one
day.
F03
The battery is overloaded.
Remove the battery from the equipment and try it
again. No change: see F01
F04
The battery is defective
A defective battery is not allowed to be used any more.
F05
The battery is partially fully discharged
Recharge the battery.
A
B
Changing the battery
This battery can be switched between 2 charge levels (4 Ah / 6 Ah).
-
4.0 Ah (72 Wh) --> better for the battery, extending its total life by about 3 times
-
6.0 Ah (108 Wh) --> long operating time per battery charge
The battery is supplied with 4.0 Ah (72 Wh).
To switch between 4.0 Ah and 6.0 Ah, proceed as follows:
Important! Read the instructions through completely before changing the battery setting!
1. Hold the button for the battery charge level indicator (A) down for about 6 seconds until the battery on the display
(B) begins to count from 1 to 9.
2. - To switch from 4 Ah to 6 Ah, press the button (A) brie
fl
y again when the number 6 is displayed. The count then
continues as normal to 9.
- To switch from 6 Ah to 4 Ah, press the button (A) brie
fl
y again when the number 4 is displayed. The count then
continues as normal to 9.
3. Once the display (B) has reached 9, the new setting “6Ah” or “4Ah” will be indicated for about 2 seconds.
The battery is now switched and ready for use.
The battery can only be switched if the number 4 or 6 is pressed. Other numbers do not have any signi
fi
cance.
This process is essential in order to avoid switching over inadvertently.
Anl_Power_X_Change_4_to_6_SPK7.indb 3
Anl_Power_X_Change_4_to_6_SPK7.indb 3
03.09.2019 13:06:29
03.09.2019 13:06:29