1. Safety instructions

1.1 Safety instructions for working with 

compressed air and blasting guns

Compressors and lines reach high temperatures
during operation. Avoid contact! Risk of burns!

Gases or vapours drawn in by the compressor
have to be kept free of constituents that may
cause fire or explosions inside the compressor.

When you disconnect the hose coupling, hold
the coupling element in your hand to prevent
injury from the whiplashing hose.

Wear goggles when working with the blow-out
gun. Injuries may easily result from foreign
bodies and blasted parts.

Never point the blow-out gun at other persons
and never use it to clean clothes that are still
being worn.

Keep these safety  instructions in a safe place.

2. Layout

1 Control knob
2 Pressure gauges
3 Quick-lock coupling
4 Oil level window 
5 Drain screw (on R 3/8” for picture)
6 Threaded nipple
7 Adjustment screw for oiler
8 Oil level window for oiler

3. Items supplied

Take all parts out of the packaging and check that
they are complete.

Combination conditioning unit R 1/4” with oiler

(Fig. 1)

Combination conditioning unit R 3/8” with oiler
(Fig. 2)

Threaded nipple (6) and quick-lock coupling(3)

Original operating instructions

4. Scope of use

Designed to reduce pressure of compressed air (inlet
pressure up to max. 10 bar).

Please note that our equipment has not been
designed for use in commercial, trade or industrial
applications. Our warranty will be voided if the
machine is used in commercial, trade or industrial
businesses or for equivalent purposes.

The machine is to be used only for its prescribed
purpose. Any other use is deemed to be a case of
misuse. The user / operator and not the manufactur-
er will be liable for any damage or injuries of any
kind caused as a result of this.

5. Technical data

Inlet pressure 

max. 10 bar

Adjustable pressure range 

up to 8 bar

6. Assembly

Appliance should be connected in the direction of the
arrow at the compressor outflow. It is also possible to
affix the appliance to the wall with the wall mount.

Connect

Push the nipple on your compressed air hose into
the quick-release coupling, the sleeve will automati-
cally spring forwards.

Disconnect

Pull back the sleeve and remove the hose.

Important. As you release the hose coupling,
hold the hose coupling part in your hand to pre-
vent injuries caused by the hose being thrown
backwards.

The compressed air hose is also fitted with a quick-
lock coupling to which accessories can be connected
as described above.

5

GB

Kombiwartungseinheit_SPK7:_  13.05.2009  13:56 Uhr  Seite 5

Summary of Contents for 01039

Page 1: ...itung Kombiwartungseinheit mit ler Original operating instructions Combination conditioning unit with oiler Art Nr 41 350 00 I Nr 01029 Art Nr 41 350 01 I Nr 01039 Kombiwartungseinheit_SPK7 _ 13 05 20...

Page 2: ...2 1 1 2 6 4 5 8 3 7 2 1 2 8 6 4 3 7 5 Kombiwartungseinheit_SPK7 _ 13 05 2009 13 56 Uhr Seite 2...

Page 3: ...s 5 Ablassschraube bei R 3 8 nicht abgebildet 6 Gewindestecknippel 7 Justierschraube f r ler 8 Schauglas f r ler 3 Lieferumfang BIld 1 2 Nehmen Sie alle Teile aus der Verpackung und ber pr fen Sie die...

Page 4: ...Wasser zu entfernen 8 Reinigung und Wartung 8 1 Reinigung Halten Sie das Ger t so staub und schmutzfrei wie m glich Reiben Sie das Ger t mit einem sauberen Tuch ab oder blasen Sie es mit Druckluft be...

Page 5: ...l level window for oiler 3 Items supplied Take all parts out of the packaging and check that they are complete Combination conditioning unit R 1 4 with oiler Fig 1 Combination conditioning unit R 3 8...

Page 6: ...Wipe the appliance with a clean cloth or blast it with compressed air at low pressure We recommend cleaning the appliance immedi ately after every use Clean the appliance regularly with a damp cloth a...

Page 7: ...cher Zustimmung der ISC GmbH zul ssig The reprinting or reproduction by any other means in whole or in part of documentation and papers accompanying products is permitted only with the express consent...

Page 8: ...8 Kombiwartungseinheit_SPK7 _ 13 05 2009 13 56 Uhr Seite 8...

Page 9: ...9 Kombiwartungseinheit_SPK7 _ 13 05 2009 13 56 Uhr Seite 9...

Page 10: ...external influences e g damage caused by the device being dropped and normal wear resulting from proper operation of the device This applies in par ticular to rechargeable batteries for which we never...

Page 11: ...emdk rpern in das Ger t wie z B Sand Steine oder Staub Gewaltanwendung oder Fremdeinwirkungen wie z B Sch den durch Herunterfallen sowie durch verwendungsgem en bli chen Verschlei ausgeschlossen Dies...

Page 12: ...dung m glichst genau Dadurch k nnen wir f r Sie Ihre Reklamation schneller bearbeiten und Ihnen schneller helfen Eine zu ungenaue Beschreibung mit Begriffen wie Ger t funktioniert nicht oder Ger t def...

Reviews: