background image

EINBREW.COM 

 EINBREW 1V1P USER INSTRUCTIONS 

 

V1.0.6 © ACKSEN LTD 2017 

 

 

 

 

 

 

 

Summary of Contents for 1V1P

Page 1: ...EINBREW COM EINBREW 1V1P USER INSTRUCTIONS V1 0 6 ACKSEN LTD 2017 1...

Page 2: ...lexible configurable and industrial grade control system all expertly engineered into an easy to install package Just plug in your heater and pump no electrician or electrical experience needed We ll...

Page 3: ...perature Probe to Brewing Vessel 12 Extending EINBREW EBC C20 Power Lead 12 Replacing user replaceable fuses 13 Drilling Holes in Stainless Steel Vessels for Heating Elements and or Temperature Probes...

Page 4: ...EINBREW COM EINBREW 1V1P USER INSTRUCTIONS V1 0 6 ACKSEN LTD 2017 4 Brew Complete 25 Cleaning 25 Troubleshooting 26 Warranty 28 Maintenance 28 Returning EINBREW EBC for repair 28 WEEE Regulations 29...

Page 5: ...eration Ensure that the supplied power lead is fully unwound during use If using any extension leads ensure that they are fully unwound and have a 16A current capacity when unwound EINBREW EBC is not...

Page 6: ...100W Maximum IEC C14 Socket manually controlled Product Weight unladen Brewing Vessels Supported 1 Temperature Monitoring YES 1 sensor RIMS Support YES HERMS Support YES Audible alarms YES Audible coo...

Page 7: ...EINBREW EBC system will come shipped with the following components When you unpack please ensure you check everything is there and if any parts are missing please contact your supplier or Support imm...

Page 8: ...be sufficiently powerful for the task importantly if using RIMS the water flow must be able to remove heat from the in circuit heating element at a sufficient rate or you may encounter issues where th...

Page 9: ...t EINBREW EBC provides precision temperature measurement and control and should provide excellent temperature control over a wide range of brewery configurations However its performance is ultimately...

Page 10: ...above Please also make sure that the inlet power cable for EINBREW EBC the outlet power cables for the heating element and pump and the temperature sensor cable will reach without being taut or presen...

Page 11: ...re of the conductors for a good fit For safety ensure that you only strip enough of the protective sheath to allow insertion of the relevant conductor into each of the screw terminals no more Screw ea...

Page 12: ...tivate Installing Temperature Probe to Brewing Vessel The EINBREW EBC comes supplied with a Temperature Probe to allow you to monitor and control your system This will either be an NTC or PT100 probe...

Page 13: ...any of this work carried out you will have to undertake the work yourself Firstly confirm that you have appropriate drill bits or hole saws etc and drill available speed etc for the job of creating t...

Page 14: ...rm that the heating system heat exchanger is warming the vessel as expected It will take time for the temperature to increase so do not expect an instant ramp to your set temperature Take care to look...

Page 15: ...LTD 2017 15 CONTROL PANEL Before beginning to make your brew let s go through the main control panel EINBREW EBC is designed to be similar to a traditional brewery control system Our diagram of the fr...

Page 16: ...Phases and the Boil Phase along with Hop Insertion timings The Up Down buttons will allow you to increment and decrement the presently displayed time The Time displayed will depend on the particular S...

Page 17: ...crement the presently displayed set temperature To switch between the different Mash Phase timings press the Set button The display will go through Mash Phase 1 to Mash Phase 9 and back to Mash Phase...

Page 18: ...e stages Set Brewing Phase Button This button has different functions depending on the presently selected Brewing Stage When a Brewing Stage hasn t been started it ll allow you to configure your EINBR...

Page 19: ...end once the preset parameters have been run through At the end of each stage you manually move to the next by pressing the Stage button and pressing Start again Pause You may Pause a Stage when it s...

Page 20: ...ied to the Set Temperature By default this is 0 3 It can be varied from 0 2 to 2 0 This is the amount of variation allowed in the Measured Temperature from the Set Temperature before heating is applie...

Page 21: ...erature for each stage and show you how to enter it Stage Temperature Time Preheat Mash In Stage 39 C N A Mashing Stage Mash Phase 1 Mash Phase 2 Mash Phase 3 Mash Phase 4 52 C 62 C 72 C 78 C 5 minute...

Page 22: ...ould be lit and the lower half of the timer display should show BOIL If it doesn t press the Phase button to cycle through the Hop Inserts until this is displayed Use the Up Down arrows in the Timer s...

Page 23: ...EN LTD 2017 23 Setting Cooling Stage Ensure that the green indicator beside the Cool section is lit signifying that we re setting up the Cooling Stage The Timer section will also display COOL Then use...

Page 24: ...s the Start button EINBREW EBC will automatically run through the Mashing Phases that you ve setup previously You ll see that the indicator will heat through each temperature step and once that s reac...

Page 25: ...tage Press the Stage button until the Cool section is selected then press the Start button EINBREW EBC will monitor until the temperature you ve setup previously has been reached whilst you engage you...

Page 26: ...f 1 C every 1 minute This will differ depending on the ambient temperature and if you have the lid on the vessels being heated on or off Also the higher the temperature the more heat losses will occur...

Page 27: ...rn on EINBREW EBC again Depending on the duration of the outage you may be able to pick off close to where you left off o Move to the relevant Brewing Stage and confirm that the time temperatures are...

Page 28: ...ttempting to remove or replace these fuses MAINTENANCE Prior to each use of the unit check the casing for signs of damage or misuse Check the leads for signs of damage ensure the outer insulation is n...

Page 29: ...C offer a product take back service For customers within the European Union only and products manufactured or sold by us when those products reach the end of their life simply send them back to us at...

Reviews: