- 8 -
Circuit Protections
■
To control the driving power of the cooling fans.
This projector detects internal temperature and automatically controls operating power of cooling fans.
The CPU checks the temperature and atmospheric pressure inside a projector. It checks a temperature using
temperature sensor-IC5801and it checks an atmospheric pressure using pressure sensor-IC886.
The CPU controls the driving power of the cooling fans so the temperature inside the projector is maintained to
normal temperature.
■
To shut down the projector.
The CPU checks temperature of Blue polarized glass (PTH901) and inhalation air(IC5801). If each part temper-
ature reaches to abnormal temperature, the CPU will turn off a projector, and will blink WARNING TEMP. indi-
cator at intervals of 0.5 seconds. Cooling fans operate until temperature returns to normal. WARNING TEMP.
indicator will stop blink, if temperature returns to normal.
●
Temperature Monitor System
Main Board
A-side
Front side
B-side
Temp. Sensor
IC2541
Temp. Sensor
(Inhalation air)
IC5801
Pressure Sensor
IC886
Temp. Sensor
(Blue polarized glass)
PTH901
Temperature sensors location
Blue polarizer unit
Summary of Contents for LC-XT4E
Page 103: ...103 IC Block Diagrams CXA2151Q RGB Matrix IC2261 CXD2064Q 3 Line Y C Separator IC2101...
Page 106: ...106 IC Block Diagrams Sii169ACT DVI Interface IC8001 PW365 Scan Converter IC301...
Page 159: ...159 MEMO...
Page 160: ...LC XT4U E APR 2006 2006 Eiki International Inc A key to better communications...