LC-XIP2000 Service
Manual Ver. A
10
END
A.No Image Troubleshooting
Start
Check LED
indicator on
keypad
Green off
Red off
yes
Green fast flashing
Red on
Change
keypad
Change
power
supply
yes
yes
yes
Check /
change lamp
door switch
Green fast flashing
Red fast flashing
Green on
Red fast flashing
Check /
change
thermal sensor
connector
Check / change
thermal switch
connector
Check /
change Lamp
/ Ballast
No trouble found
Check fan pin2
voltage - 5V
(J1,J4,J5,
J6,J15)
no.
Change
failed fan
Change Main Board,
but keep the same
24LC256
no
Yes
no
yes
END
yes
no
no
no
yes
no
END
yes
yes
no
no
no
no
yes
yes
no
no
Green on
Red off
yes
no
Troubleshooting
Summary of Contents for LC-XIP2000
Page 4: ...LC XIP2000 Service Manual Ver A 4 Chapter 1 Trouble shooting...
Page 6: ...Troubleshooting...
Page 7: ...LC XIP2000 Service Manual Ver A 7 Troubleshooting LED Lamp Indicator...
Page 18: ...LC XIP2000 Service Manual Ver A 18 Chapter 2 M B Firmware Download...
Page 24: ...24 Chapter 3 Disassembly...
Page 25: ...25 Disassembly...
Page 27: ...27 Disassembly Screws List...
Page 32: ...32 5 Key Pad Disassembly Disassembly A Take off 4 M3 5 screws...
Page 33: ...33 6 IO Case Disassembly Disassembly A Take off 2 M3 8 screws...
Page 37: ...37 10 Inlet Fan Disassembly Disassembly A Take off Fan no screws...
Page 45: ...45 Disassembly 18 Take out Plate_MB_GND A Unscrew BM3x8 to disassemble Plate_MB_GND part...
Page 48: ...LC XIP2000 Service Manual Ver A 48 Chapter 4 Service mode and Calibration...
Page 56: ...LC XIP2000 Service Manual Ver A 56 Chapter 5 RS232 Command...
Page 58: ...LC XIP2000 Service Manual Ver A 58 RS232 Command RS232 command...
Page 59: ...LC XIP2000 Service Manual Ver A 59 RS232 Command RS232 command...
Page 60: ...LC XIP2000 Service Manual Ver A 60 RS232 Command RS232 command...