11
•Timer:
The timer is avaible in two options:
•
Stand alone timer
•
Cooking zone timers
One timer is available for each cooking zone, and one for
stand alone timer. The timers can be used parallel. The
maximum time value can be set to 99 min. Value less
than 1 min. is indicated in seconds.
The
Stand alone timer
has the behavior of an egg timer.
To active this function, ensure that no cooking zone has
been selected, then press Timer select key [F area], now
the user can set timer value on the slider [B area].
To deactivate this function, the user can set timer value to
0
or press the ON/OFF key [A area] twice.
The
Cooking zone Timers
can be used to switch off a
cooking zone automatically after the set time has
run out. To activate this function, the user can select
the corresponding cooking zone, using E
1 -
E
2 -
E
3 -
E
4
key [E area]; after that set a power level (greater than 0),
and then press the Timer select key [F area], after that
the user can set timer value on the slider [B area]. In case
the timer is set and no cooking zone is activated within 10
sec., the displays [E area] are switched off.
To deactivate this function, the user can set time value
to
0
or switch off corresponding cooking zone (select the
cooking zone, using E area, and move the slider, B area
to
0
)
.
If a timer runs out the alarm mode starts. The alarm
can be stopped by any key operation.
•Pause function:
During active pause function no power will be emitted
and cooking process is interrupted.
When at least one cooking zone is active, the heating
elements may be switched off by pressing the Pause key
[D area] for at least 1 sec, and in the display will show
this symbol:
I I.
The programmed timers (also the stand alone timer) are
stopped and not continued during the pause. Automatic
Heat-up and Booster functions are also switched off on
all cooking zones during pause activation. Unlike the
Residual heat and Operating time limitation continue and
are not stopped.
This function may be activated also if cooking zone
specific errors occur, unlike if a general error occurs
during the Pause the hob switches off.
The Pause mode can continue for max. 10 minutes, after
which the hob turns off automatically.
In this 10 minutes (max time) the coooktop may be
switched off at any time by the user with the ON/OFF
key [A area].
To deactivate the Pause mode press the Pause key [D
area], thereafter any other key (not the same again) has
to be actuated for 10 sec. This recovers the conditions
before the pause mode.
The led of the Pause mode [D
1
area] is illuminated when
the pause function is active, and blinking in two cases:
during the waiting time for a second key be activated for
ending the pause; and with recall function is possible
after switching on again.
•Recall function:
By using the recall function the settings can be recovered
quickly when the hob was switched off using the ON/OFF
key [A area] accidentaly.
The restorable informations are:
•
Cooking levels of all cooking zones
•
Minutes and seconds of active cooking zone
related timers
•
Heat-Up Automatic and Booster functions
•
Child-lock
•
Bridged zones
•Operation Time Limitation [Automatic Switch Off]:
The Operation Time Limitation is an additional safety
feature to turn OFF cooking zone after certain time with
no operation to the corresponding cooking zone by the
user. The time after which the cooking zone is turned
OFF is mentioned in the table below. Each user operation
related to the cooking zone will reset this time limit.
Cooking
level
Max. Operation time
(h)
Warming level
2
1
6
2
6
3
5
4
5
5
4
6
1.5
7
1.5
8
1.5
9
1.5
P
5 min.
Summary of Contents for 60 Fusion IF
Page 4: ...4 Induction A B Fig 5 Fig 6 Ø 90 mm Ø 110 mm Ø 70 mm Ø 90 mm Ø 90 mm Ø 110 mm ...
Page 7: ...7 3 5 2 4 1 N L2 L1 2P N L1 3 5 2 4 1 L2 2P 230V L1 3 5 2 4 1 N 1P 1N Fig 9 ...
Page 15: ...15 ...
Page 23: ...23 ...
Page 31: ...31 ...
Page 39: ...39 ...
Page 47: ...47 ...
Page 48: ...3PCLIOB4S640XE1 20 07 2021 ...