When the CO Alarm detects abnormal levels of CO (above 50ppm CO) the 

red

light

starts to flash and the horn will sound within 90 minutes. At higher levels

of CO the alarm will turn on sooner (see table B - page 9).

The CO Alarm will automatically reset once the CO has cleared. Pressing the
test/hush button resets the CO Alarm immediately (below 300ppm CO). If CO is
still present the red light and horn will turn on again after about 4 minutes.

The CO Alarm is no substitute for keeping chimneys and flues clear and in good
condition, and all of your appliances serviced regularly according to the
manufacturers’ instructions.

Do not fit alarm until all building work is completed to avoid contamination.

2. WHAT TO  DO WHEN THE  ALARM  SOUNDS

(1)

Open the doors and windows to ventilate the area.

(2)

Turn off all fuel appliances where possible and stop using them. (The alarm

can be silenced immediately by pushing the test/hush button).

(3)

Evacuate the property leaving the doors and windows open.

(4)

Get medical help immediately for anyone suffering the effects of Carbon

Monoxide poisoning (headache, nausea), and advise that Carbon Monoxide
poisoning is suspected.

?

4

?

B15584/R0/225EN&220EN/U&C  31/8/06  10:51 AM  Page 4

www.acornfiresecurity.com

www.acornfiresecurity.com

Summary of Contents for Professional Ei220EN

Page 1: ...he product is being used It contains vital information on the operation and installation The leaflet should be regarded as part of the product If you are just installing the unit the leaflet must be g...

Page 2: ...INSTALLING YOUR CARBON MONOXIDE ALARMS TESTING YOUR CARBON MONOXIDE ALARMS MAINTAINING CARBON MONOXIDE ALARMS LIMITATIONS OF CARBON MONOXIDE ALARMS HOW TO PROTECT YOUR FAMILY TECHNICAL SPECIFICATIONS...

Page 3: ...liance In rooms remote from the appliance install at breath level where the light indicators can be seen Regularly check that the green power light is on Important The CO Alarm will not work if the ma...

Page 4: ...ion and all of your appliances serviced regularly according to the manufacturers instructions Do not fit alarm until all building work is completed to avoid contamination 2 WHAT TO DO WHEN THE ALARM S...

Page 5: ...er 3 CARBON MONOXIDE THE SILENT KILLER 2 1 What is Carbon Monoxide Congratulations on becoming the owner of an Ei Carbon Monoxide Alarm This will help protect you and your household from the dangerous...

Page 6: ...ing appliances Blocked or cracked chimneys flues Blocked vents or draught proofing which makes areas with fuel burning appliances or fireplaces airtight Engines of cars lawnmowers etc left running in...

Page 7: ...ight headache as a lower level for a longer time e g 150 ppm for 90 minutes Table A shows how exposure to different concentrations of CO generally affects people Many cases of reported Carbon Monoxide...

Page 8: ...2 3 hours 1 600 Headache dizziness and nausea within 20 minutes Death within 1 hour 3 200 Headache dizziness and nausea within 5 10 minutes Death within 25 30 minutes 6 400 Headache dizziness and nau...

Page 9: ...elp arrives and the alarm may have stopped sounding Although your problem may appear temporarily solved it is crucial that the source of the CO is determined and appropriate repairs made NEVER IGNORE...

Page 10: ...etected for least about 90 minutes Red light flashes 4 times in 2 seconds every 40 seconds 100 ppm CO detected for least about 40 minutes Red light flashes 8 times in 2 seconds every 40 seconds 300 pp...

Page 11: ...open flued appliance and Locate an alarm in a room where the occupant s spend most of their time e g sitting room and In a bedsit the CO alarm should be placed as far away from the cooking appliance...

Page 12: ...where it could be accidentally turned off or removed 12 In a bathroom or other areas where the CO alarm may be exposed to water splashes dripping or condensation e g above an electric kettle 13 Near p...

Page 13: ...me side of the partition as the potential source In rooms with sloped ceilings the CO alarm should be located at the high side of the room see fig 3 300mm 150mm 1 to 3 m 1 to 3 m DEAD AIR DON T LOCATE...

Page 14: ...t is possible to view the three light indicators when in the vicinity of the alarm 14 CO Alarm about 1 to 2m Figure 4 Location in bedroom rooms remote from the appliance i e at breathing level 300mm C...

Page 15: ...work can contaminate the sensor and cause problems it will also invalidate the guarantee If it must be installed cover it completely particularly around the edges with a dust cover until all cleaning...

Page 16: ...m the ceiling wall locate the wire entry slot over the wires and mark the two mounting screw locations Screw the unit to the ceiling wall ensure screws do not penetrate buried wires The unit can also...

Page 17: ...terminal marked N The alarm does not need to be earthed however for convenience a spare terminal no 5 is provided to hold an earth wire if present 7 Turn on the mains power to the CO Alarm circuit 17...

Page 18: ...cations Drill suitable holes 6mm drill then insert the plastic anchors and screw the unit to the ceiling wall 4 Insert the plug into a suitable socket Warning Do not open apart from the cover shown in...

Page 19: ...hes every 40 seconds it means the self checking circuit has detected a fault Press and hold the test hush button If the amber light flashes without the horn sounding the sensor is faulty 4 If the Alar...

Page 20: ...stinguish between them in an emergency 7 MAINTAINING YOUR CO ALARM Clean the outside case by occasionally wiping with a clean damp cloth after first disconnecting the mains supply on an Ei225EN unit a...

Page 21: ...abel on the side wall is exceeded Product Disposal The crossed out wheelie bin symbol on the product means that it should not be put into household waste Please recycle where facilities exist Check wi...

Page 22: ...ible 2 Carbon Monoxide must enter the unit for it to be detected There may be Carbon Monoxide in other areas of the house e g downstairs in a closed room etc but not in the vicinity of the CO Alarm Do...

Page 23: ...ly The CO Alarm must be replaced after up to 6 years operation see Replace by date on side wall label 5 CO Alarms are not a substitute for life insurance House holders are responsible for their own in...

Page 24: ...ce is working A naked gas flame which is yellow or orange instead of the normal blue Family members including pets exhibiting the flu like symptoms of CO poisoning described above If any of these sign...

Page 25: ...heating 8 Children should be warned of the dangers of CO poisoning and instructed never to touch or interfere with the CO Alarm Do not allow small children to press the test hush button as they could...

Page 26: ...unit is alarming after sensing CO pressing the test hush button will immediately stop the horn the red light will continue to flash If CO is still present the red light and the horn will turn on again...

Page 27: ...crew unit from wall End of Life Indication Amber light flashes every 45 seconds after 6 years to show the unit must be replaced CO Alarm Memory A unit will indicate if it has been in alarm previously...

Page 28: ...ate the nature of the fault where the CO Alarm was purchased and the date of purchase 12 GUARANTEE Ei Electronics guarantees the Ei225EN Carbon Monoxide Alarm for five years from the date of purchase...

Page 29: ...o where it was purchased or alternatively to Ei Electronics carefully packaged with the problem clearly stated see section 11 Getting the CO Alarm Serviced along with proof of the date of purchase We...

Page 30: ...test hush button to reset the unit If the beeping and the amber light flashing re occurs replace the unit 3 AMBER LIGHT FLASHES EVERY 40 SECONDS The unit has been operating for up to 6 years and must...

Page 31: ...bly defective and should be replaced follow the instructions in section 7 on How to disconnect and remove your alarm and then see section 11 Getting the CO Alarm Serviced 4 TEST HUSH BUTTON DOES NOT S...

Page 32: ...Ei Electronics 2005 P N B15584 Rev 0 B15584 R0 225EN 220EN U C 31 8 06 10 51 AM Page 32 www acornfiresecurity com www acornfiresecurity com...