E & OE  As our policy is one of continuous product development, we reserve the right to alter product details without prior notice

.               

Ei100C DataSht RevB

 

 
 

Shannon Free Zone, Shannon, Co. Clare, Ireland. 

Ph.

+353 61 471277   

Fx.

+353 61 471053   

 

Email.

 [email protected]

 

 

Web:

 www.eielectronics.com 

 

 

Model 

Ei 100C Ionisation 

 

High sensitivity 

– responds to all standard fires 

 

Dual Ionization chamber - quick response fast 
flaming fires 

 

Battery powered 

– 9V supplied) 

 

Interconnect up to 12 other alarms 

 

Needs no wiring 

 

Missing battery indicator 

 

Low battery warning 

 

Built in sounder  

 

Test button 

 

Kitemarked to BS EN 14604:2005 

 

5 year guarantee 

 
 

Product Description 

 

The Ei100C is an Ionisation Smoke Alarm that runs on a 
9V alkaline battery (supplied with the alarm).  
 
Ionisation smoke alarms operate on the principle that 
electrical current flowing between electrodes in an 
ionization chamber is reduced when smoke particles 
enter. 
 
Ionisation technology gives a rapid response to fast 
flaming fires 
 
The Ei100C is easily installed and comes supplied with 
all necessary screw fixings. 
 
The Ei100C is fitted with a warning flag that pops up 
when the battery is removed. This prevents the cover 
from closing when there is no battery fitted to the unit. 
When the battery is being installed or changed, this flag 
must be held down while gently pushing the battery into 
the battery holder. 
 
When the battery is first connected, the alarm may sound 
for 2-3 seconds 

– 

this is normal and means that the 

battery is connected correctly

 

 

Operation 

 

 

Interconnect up to 12 other alarms (9V ionisation, 
optical or heat) when one senses smoke, all alarm. 
Helps ensure warning will be heard throughout the 
house

 

 

The smoke detector will activate the built in sounder 
upon sensing smoke particles 

 

 

The smoke detector will automatically reset itself 
and silence the sounder when smoke particles are 
no longer present in the sensing chamber 

 

 

The built in sounder will provide a minimum sound 
output of 85dB at 3m 

 

 

The smoke detector has a built in warning flag to 
prevent installation of the detector without a battery 
fitted 

      

 

 

The “Test” button will perform a self test and sound 
the horn (it may take up to 10 seconds) 

 

 

The smoke detector will emit a beep every 40 
seconds to indicate that the battery back up is 
depleted and needs replacing 

 
 

9V BATTERY POWERED 

 