background image

 

 

MSD-350 

WIRELESS SMOKE DETECTOR 

msd-350_en 03/19 

The MSD-350 detector can detect the early stages of fire development when there is some visible smoke. It can 
operate as a stand-alone device or as part of the wireless system. The detector is supported by: 

  PERFECTA 16-WRL, PERFECTA 32-WRL and PERFECTA-T 32-WRL control panels, 

  MICRA alarm module (firmware version 2.02 or newer), 

 VERSA-MCU 

controller, 

 MTX-300 

controller. 

This manual applies to the detector with firmware version 1.0. The rating plate of the device is located inside the 
enclosure. 

1.  Features 

  EN 14604 compliant visible smoke sensor. 

  Detection of optical chamber fouling. 

  Red LED for optical signaling. 

 Built-in 

sounder. 

 Test 

feature. 

  Tamper protection against enclosure opening (when working in a wireless system). 

  Battery status control. 

2.  Description 

Smoke detection 

An optical method is used for the detection of visible smoke. The detector automatically compensates for 
gradual changes in the optical chamber caused by deposition of dust. When the concentration of smoke in the 
optical chamber exceeds a given threshold, an alarm is triggered.  

Fire alarm signaling 

The alarm is indicated visually (LED steady light) and acoustically (intermittent sound) for 5 minutes. Pressing 
the test/reset button (designated with the letter A in Figure 2) during the alarm will clear the alarm condition and 
will block the smoke detection function in the detector for 5 minutes. 

Operating modes 

You can set the operating mode using the jumper (Fig. 4): 

  jumper removed – stand-alone mode. 

  jumper installed – working in 433 MHz wireless system. The detector is operating similarly as in the stand-

alone mode, but it additionally: 

  sends radio transmissions, 

  supervises the tamper switch state. 

Working in wireless system 

Radio transmissions 

Every 15 minutes, the detector sends a radio transmission with information about its state (periodic 
transmission). This allows the system to supervise the presence and performance of the detector. Additional 
communication takes place in the case of alarm (smoke is sensed by the detector) or tamper (tamper switch has 
been opened) and after restore of alarm (smoke is sensed no more by the detector) or tamper (tamper switch 
has been closed). 

Test mode 

The test mode is turned on for 20 minutes after inserting the battery or opening the tamper contact. When the 
detector is running in the test mode, the LED indicates: 

  tamper – ON for 2 seconds, 

Summary of Contents for MSD-350

Page 1: ...ed Fire alarm signaling The alarm is indicated visually LED steady light and acoustically intermittent sound for 5 minutes Pressing the test reset button designated with the letter A in Figure 2 during the alarm will clear the alarm condition and will block the smoke detection function in the detector for 5 minutes Operating modes You can set the operating mode using the jumper Fig 4 jumper remove...

Page 2: ...ll plugs delivered with the detector are intended for brick concrete and similar mounting surfaces For other surfaces e g drywall wood styrofoam use other wall plugs as required 9 Replace the detector cover and lock it with the screw 10 Press and hold down the test reset button designated with the letter A in Figure 2 Alarm should be triggered 11 If in the premises where the detector is installed ...

Page 3: ...ed 5 Battery replacement The used batteries must not be discarded but should be disposed of in accordance with the existing rules for environment protection When the battery needs to be replaced the battery voltage drops below 2 75 V the detector informs you about it by means of LED and sounds 3 short flashes of the LED and 3 short beeps every 30 seconds 1 Remove the screw fastening the cover Fig ...

Page 4: ...ncil of 16 April 2014 on the harmonization of the laws of the Member States relating to the making available on the market of radio equipment and repealing Directive 1999 5 WE The CNBOP PIB Certification Body in Józefów issued the Certificate of Constancy of Performance 1438 CPR 0623 for the construction product MSD 350 Wireless Smoke Detector confirming its compliance with the requirements of EN ...

Reviews: