background image

will stop when the button is released. Pressing the test button
simulates the effect of smoke or heat  during a real fire and is
the best way to ensure the Alarm is operating correctly.

WARNING: DO NOT TEST WITH FLAME

This can set fire to the Alarm and damage the house

We do not recommend testing with smoke or heat as the
results can be misleading unless special apparatus is used.

(iii) Check for any sign of 

contamination

such as cobwebs or

dust and clean the alarm as described in the “

CLEANING

YOUR ALARM

” section on page 6, if necessary.

(iv) 

Interconnected Alarms only - 

Test the first unit by

pressing the button for 10 seconds. All the units should alarm
within 10 seconds of the first horn sounding. The red light on
the first unit only will flash about once a second. Check all the
other units similarly.

(v) Check the functioning of the mains battery back-up directly

after installation

and then 

at least yearly

as follows:

- Turn off the mains power at the distribution board and check

that the green indicator light is extinguished.

- Press the test button and ensure the horn sounds loudly  for

10 seconds.

Turn on the mains supply at the distribution board only if the
unit passes the above test.

Note:

If the mains is disconnected and the battery is almost

depleted the unit will beep every 40 seconds for at least 30 days.

(vi) Monitor the alarm over a short period of time for any
beeps.

5.1 If the unit is beeping

The Alarm automatically monitors the battery every 40
seconds to ensure that it is satisfactory. If it is depleted it will
give a short beep every 40 seconds.

Models Ei141, Ei144 & Ei146 only

Before replacing the battery, check that the beeps are not
due to one of the following:

(i) battery snaps not connected properly.

(ii) On the 

Optical Smoke Alarm

only (Ei146) if the unit

beeps and the red light does not flash at the same time it
indicates a problem with the smoke chamber - see

CLEANING YOUR  ALARM

” section on page 6.

(iii) If the beeps have continued for over 20 minutes (and
the other causes of beeps have been ruled out - see

TROUBLESHOOTING

” section on page 11) the battery

must be replaced.

See “

CHANGING THE  BATTERY

” section on page 4.

5

B16009-R0-160RC SERIES-U&C  17/1/07  11:13 AM  Page 4

Summary of Contents for B16009-R0-160RC Series

Page 1: ...E FROM THE BASE PLATE BY MOVING IT VERTICALLY DOWNWARDS TOWARDS THE FLOOR REMOVE ALARM LOCATE REMOVAL SLOT LOCATE THE ARROW ON THE FRONT FACE OF THE ALARM THE SLOT IS LOCATED DIRECTLY ABOVE THE ARROW...

Page 2: ...weekly press and hold the test button on the alarm for 10 seconds The alarm will sound loudly and the red light on the cover should flash rapidly All the other interconnected alarms should sound If a...

Page 3: ...it cannot be replaced on the base unless a battery is installed 7 Press and hold the test button horn should sound loudly 8 Reinstate mains power to alarm green light on cover should come on We recomm...

Page 4: ...een indicator light is extinguished Press the test button and ensure the horn sounds loudly for 10 seconds Turn on the mains supply at the distribution board only if the unit passes the above test Not...

Page 5: ...after test hush button has been pressed These two beeps should not be confused with low battery beeps A unit will operate from the mains alone even with a fully depleted or a defective battery and giv...

Page 6: ...n of smoke heat or noise to indicate that there is a fire you should get your family into a safe place before you start investigating Check the house carefully in case there is a small fire smoulderin...

Page 7: ...ion of cobwebs dust or grease If unit has been damaged in any way or does not function properly do not attempt a repair Return the Alarm see GETTINGYOUR ALARM SERVICED section on page 10 This applianc...

Page 8: ...er of reasons for this The Alarms will not work if the mains power is off and the battery is depleted On the Ei141 144 146 alarms the batteries should be replaced every three years as a precaution or...

Page 9: ...or replacement put it in a padded box and send it to Customer Assistance and Information at the nearest address given on the Alarm or in this leaflet Do not snap on to the mounting plate as this conne...

Page 10: ...y is correctly connected and the unit has beeped for over 20 minutes the battery is probably depleted Obtain a new battery disconnect the mains then remove the alarm and replace the depleted battery O...

Page 11: ...nal is transmitted to all units 2 One or more of the connections may not be correctly connected We recommend you consult a qualified electrician Aico Ltd Mile End Business Park Maesbury Rd Oswestry Sh...

Page 12: ...1 REGULAR CHECKS 230V SMOKE HEAT ALARMS USER INSTRUCTIONS Look for Constant green light Red light flash every 40 sec Press test button for 10 sec Alarm will sound loudly Vacuum around side vents to cl...