EHV GmbH • Entwicklung | Herstellung | Vertrieb • Hauptstraße 131 • 01744 Dippoldiswalde
5
CONSTRUCTION MANUAL
Kiln shell of the Kanuk® with hotplate
Step I
Push the hangers at the top and bottom
into the first and last radiation tube.
The side panels will be clipped into the
bottom hangers.
Step II
Fix the side panels with the accompanying
screws at the top hangers.
Self-closing door layout I
Remove the circlip of the door-fixing bolt. Now pull the bolt
to the top and push it into the torsion spring. The medium
hanger of the spring will be fixed on the doorframe. The ends
of the springs are to be fixed behind the door suspension.
Now return the bolt to the primary position and fix it with the
circlip. Please make sure to fix the door additionally during
the entire process.
1.4. 1.4. Combustion air supply
The combustion air supply is sufficient for Kanuk® hot-air kilns up to a nominal
heating capacity of 27 kW, provided there is at least one door or
window to be opened. Furthermore, the room needs a cross-section of
at least 150 cm². The room must not fall below 4 m³ per kW of nominal
heating capacity.