5 Commissioning
5.3
Establishing the electrical mains connection
WARNING
Ensure that the electrical connection is properly installed.
Only connect the device to voltage sources earthed in accordance with the
safety regulations (mains connection of buildings or mains junction box e.g.
on construction sites).
The connection plugs must not lie on the floor and must always be dry. Do
not touch the connectors with wet hands.
All live parts in the intended working area for cleaning work, e.g. devices,
cables, sockets etc. must be water-jet proof in accordance with the safety
regulations.
Depending on device, the electrical mains connection (mains connection of
buildings or mains junction box e.g. on construction sites) must adhere the
Technical Data (see Section 3.6) and
●
comply with the electrical values indicated on the type plate of the device
●
ensure trouble-free constant operation.
The mains connection must be equipped with a residual current circuit breaker
30 mA and protected via circuit breaker as follows
●
DE Version: Mains voltage 230 VAC with 16 A (slow blow)
●
UK Version: Mains voltage 240 VAC with 13 A (slow blow).
The high pressure cleaner is supplied with a 5 m long mains cable.
When using extension cables, the relevant national safety regulations must be
observed. The cross section of the individual cable wires for extension cables
must be at least
●
1,5 mm² for a length up to 10 m
●
2,5 mm² for a length more than 10 m.
Use extension cable H07RN-F 3 G, 1,5 mm² or 2,5 mm². The plug
connections must be water-jet proof in accordance with safety regulations.
When using a cable drum, the extension cable must always be unwound
completely.
For the electrical connection proceed as follows:
Make sure, the device switch On/Off (2, Fig. 6 - 1) is switched off
(position 0).
Unwind the mains cable from the holder and place it on the floor. When
using extension cables, unwind the cable from the drum and place it on the
floor.
Plug the mains cable plug into the socket.
For the electrical connection proceed as follows:
Make sure, the device switch On/Off (
2
, Fig. 6 - 1) is switched off
(position 0).