EHRLE KD 2x2 Series Operator'S Manual Download Page 1

High Pressure Cleaner - Cold water, mobile

Series KD 2x2

Installation and Operating Instruction

301801-DE/UK-A • 1/2021 • H.S

Operator

KD523 Premium (DE/UK)

English

KD523 Standard (DE/UK)

Summary of Contents for KD 2x2 Series

Page 1: ...High Pressure Cleaner Cold water mobile Series KD 2x2 Installation and Operating Instruction 301801 DE UK A 1 2021 H S Operator KD523 Premium DE UK English KD523 Standard DE UK...

Page 2: ...the European Directives This product is used like follows marked Development Christoph N ldner Reiner Ehrle Head of Development CEO Dietenheim 01 12 2021 Relevant EC Directives 2000 14 EC 2006 42 EC 2...

Page 3: ...ing and moving loads 12 2 6 Periodic inspections 13 2 7 Guidelines for liquid sprayers 13 2 8 Design changes to the device 13 2 9 Safety devices 13 3 Product description 3 1 Device views Series 2x2 St...

Page 4: ...5 1 General Informationen 34 6 5 2 Cleaning detergent operation 35 7 Decommissioning 7 1 Temporary decommissioning 36 7 2 Decommissioning for a longer period of time 37 8 Maintenance 8 1 General Infor...

Page 5: ...e Series 2x2 and must be kept at the operating site and be available at all times For the High Pressure Cleaner cold water mobile Series 2x2 the manual contains information on User information Safety...

Page 6: ...inology High Pressure Cleaner cold water mobile Series 2x2 is used 1 4 Meaning of the emphasis The emphasis used in this manual have the following meanings WARNING Warning precedes operating procedure...

Page 7: ...trigger gun surfaces of the cleaning objects or device components can become hot Touching hot surfaces or hot water can cause burns or scalding of the skin surface Make sure surfaces have cooled befor...

Page 8: ...blies or components General Information General additional information Information on recycling General information on recycling Information zur Entsorgung Allgemeine Informationen zum sach und umwelt...

Page 9: ...pressure cleaner must be taken out of operation immediately Faulty insufficient or defective high pressure cleaners must not be put into operation Before commissioning carry out a visual inspection fo...

Page 10: ...ances using suitable collection systems Dispose of used materials in an appropriate and environmentally friendly manner Observe the local regulations According to environmental regulations waste water...

Page 11: ...nstallation and Operating Instruction and can therefore guarantee safe handling of the device or are instructed and trained on the device Children as well as persons with reduced physical sensory or m...

Page 12: ...with the skin Asbestos containing and other materials containing substances hazardous to health must not be sprayed off Information on hearing protection If the sound levels exceed the permissible va...

Page 13: ...lity or warranty will be accepted see Section 1 7 Warranty and Liability 2 9 Safety devices Safety devices serve to protect the user and must not be suspended or circumvented in their function The hig...

Page 14: ...ws Series 2x2 Standard 2 3 4 5 6 8 1 7 11 9 10 1 Trigger gun 7 Unloader valve 2 Device switch On Off 8 Spray lance 900 mm with vario nozzle 3 Connection water inlet with filter 9 Power cord 4 High pre...

Page 15: ...11 10 13 12 1 Trigger gun 8 Unloader valve 2 Hose reel 9 Spray lance 900 mm with rotary nozzle 3 Device switch On Off 10 Spray lance 900 mm with vario nozzle 4 Connection water inlet with filter 11 Po...

Page 16: ...ter mobile Series 2x2 3 Product information 3 3 Type plate device version Standard KD523 Standard 3 4 Type plate device version Premium KD523 Premium 3 5 Serial number The serial number on the type pl...

Page 17: ...5 Main fuse slow blowing A 16 13 Residual current circuit breaker max allowed residual current mA 30 30 Extension cable up to 20 m Wires 3 x 3 x mm2 2 5 2 5 Water connection Max feed pressure bar 5 5...

Page 18: ...K Masse und Abmessungen Weight Standard with packaging Premium with packaging kg kg 33 37 35 39 33 37 35 39 Length with packaging mm 400 420 400 420 Width with packaging mm 600 660 600 660 Height with...

Page 19: ...ered WARNING Danger with heavy loads The High Pressure Cleaner cold water mobile Series 2x2 weigh depending on type from 33 kg to 35 kg with packaging 37 kg to 39 kg A person is not allowed to lift an...

Page 20: ...High Pressure Cleaner cold water mobile Series 2x2 4 Installation 4 1 Accessories for KD523 Standard High pressure cleaner Spray lance 900 mm with vario nozzle Trigger gun HP Hose DN6 10 m Water inle...

Page 21: ...aner cold water mobile Series 2x2 4 Installation 4 2 Accessories for KD523 Premium High pressure cleaner Spray lance 900 mm with vario nozzle Spray lance 900 mm with rotary nozzle Trigger gun HP Hose...

Page 22: ...ruction provides a general example of assembling the device version Standard For device assembly proceed as follows f Provide the filter to the water inlet Mount the filter to the water inlet f Connec...

Page 23: ...ck lock arrests fully forward again f Connecting to the water supply net For the water supply connect the water supply hose 1 2 DN13 to the filter 4 3 2 Device version Premium General information The...

Page 24: ...position Let the crank handle engage again in the end position f Mounting the HP Hose to the hose reel Unwind HP Hose and lay out straight Attach the HP Hose with the hose end without bend protection...

Page 25: ...ecting the HP Hose to trigger gun Attach the hose end with the bend protection to the trigger gun and tighten by hand f Mounting the trigger gun onto the spray lance Pull back the quick lock see figur...

Page 26: ...ns incorrectly consult the EHRLE customer service immediately 5 1 Select location for device operation WARNING Select a suitable and permissible operating location The local regulations concerning the...

Page 27: ...ion see Section 3 6 Technical Data The regulations of the relevant water supply company must be observed According to EN 61 770 the high pressure cleaner must not be directly connected to the public d...

Page 28: ...s connection must be equipped with a residual current circuit breaker 30 mA and protected via circuit breaker as follows DE Version Mains voltage 230 VAC with 16 A slow blow UK Version Mains voltage 2...

Page 29: ...Plug the mains cable plug into the socket 5 4 Commissioning the device For commissioning the device proceed as follows f Open the water supply from the tap water network via the shut off valve f Swit...

Page 30: ...ries 2x2 6 Operation 6 Operation 6 1 Control and indicator elements of the device Device version Standard Device version Premium 2 3 4 1 2 3 4 1 1 Trigger gun 3 Pressure gauge 2 Device switch On Off 4...

Page 31: ...nger WARNING In case of electrical accidents never directly touch persons exposed life threatening voltages In the event of accidents with persons at life threatening voltages immediately switch off t...

Page 32: ...ERGENCY STOP Switch off in case of danger The water jet emerging from the trigger gun must not be directed at live electrical components or devices machines devices lines sockets etc Before cleaning d...

Page 33: ...e unloader valve clockwise the operating pressure increases turning counterclockwise it decreases f The operating pressure can be read off the pressure gauge 3 Fig 6 1 while the trigger gun 1 Fig 6 2...

Page 34: ...regulations WARNING Risk of explosion due to use of inadmissible detergents Never aspirate solvent containing liquids such as paint thinners petrol oil or similar liquids The spray of solvents is high...

Page 35: ...uring operation the cleaning detergent is now automatically sucked in via the high pressure injector and mixed with the high pressure jet Depending on the setting of the adjustable nozzle the cleaning...

Page 36: ...ff valve f Remove water inlet hose from filter on connection water inlet see Section 3 fittings of the water supply network or water tap f Pull the trigger lever 4 Fig 6 2 of the trigger gun until the...

Page 37: ...of 48 7 Decommissioning 7 2 Decommissioning for a longer period of time If the high pressure cleaner is to be taken out of operation for a longer period of time refer to Section 7 1 and take it out of...

Page 38: ...a long service life Maintaining the performance 8 2 EHRLE Maintenance and Inspection Contract With the sale of the high pressure cleaner the manufacturer EHRLE offers a maintenance contract or especia...

Page 39: ...ustomer service Customer service High pressure pump Oil leakage Customer service Weekly Water inlet filter Check filter for dirt and clean if necessary see section 8 3 2 Trained operator Filter from d...

Page 40: ...es are empty 8 3 1 2 Rinse high pressure cleaner with antifreeze agent General Information Observe the handling instructions of the antifreeze manufacturer Proceed as follows f Provide commercially av...

Page 41: ...g and low durability Bursting or leaky HP Hoses can cause hot high pressure water or steam to escape This can endanger life and limb of persons Before each commissioning of the high pressure cleaners...

Page 42: ...e switched on Check that the power supply cable is plugged in Connect the power supply cable to the building power supply or mains junction box Trained operator Building supply or mains junction box c...

Page 43: ...to normal operation Contact customer service Customer service Internal control circuits or components defective Replace defective components Customer service No pressure build up with high pressure cl...

Page 44: ...301801 1 2021 H S 44 of 48 Operating Instruction High Pressure Cleaner cold water mobile Series 2x2 10 General notes 10 Notes...

Page 45: ...301801 1 2021 H S 45 of 48 Operating Instruction High Pressure Cleaner cold water mobile Series 2x2...

Page 46: ...lve switching during closed trigger gun Kontrolliert Checked Arbeitsdruck Kaltwasserbetrieb in bar Operating pressure cold water mode in bar Aufnahmeleistung bei max Arbeitsdruck in A Electric consump...

Page 47: ...water mobile Series 2x2 Proof of customer service Device type Manufacture no Commissioning on Inspection carried out on Findings Signature Inspection carried out on Findings Signature Inspection carr...

Page 48: ...EHRLE GmbH D 89165 Dietenheim Germany EHRLE service near to you Adresses phone numbers etc you will find under www ehrle com Subject to change without notice Reprint prohibited...