 Device should only be opened by a qualified technician! 

● 

Device must be protected from heat and moisture!

 

 

 

 

 To avoid exposing yourself to the risk of an electric shock, do not open the housing for general 

use. There is a certain risk to get in contact with non-insulated parts inside the housing that carry a 
high voltage.  

Opening the housing is only permitted to perform the initial configuration if the power connection 
has  been  disconnected  beforehand.  Repairs  should  only  be  performed  by  qualified  customer 
service. 

 

 

This devise is not waterproof. To avoid the risk of electric shock protect the device from dripping 

water, splashing water, rain and moisture. 

 

 

Do not place any fire source on this device (e.g. burning candles). 

 

 

Avoid installing the device in an insufficiently ventilated, very humid or hot place. 

 

To  completly  disconnect  the  device,  all  plugs  must  be  pulled  out.  To  avoid  any 
damage disconnect the Net-scale when not in use for a longer periode of time. 

 

 

 

When disposing, do not mix the product with ordinary household waste. There 

is a separate collection system for used electronics which ensures that the materials 
are proper recycled according to legislation rules. 

 

Summary of Contents for Net-Scale V13

Page 1: ...V1 2...

Page 2: ...Set Zero 01 11 Set Tare 02 11 Delete Tare 03 11 Set Fixtare 04 11 Select scale 05 11 Register weight at stability 10 11 Manual registration 12 12 Firmware version F0 12 Set date time F1 12 Query for...

Page 3: ...design features This allows you to easily distinguish the following elements Normal text Enumerations Action steps Table titles and illustrations are printed in bold Tips contain additional informati...

Page 4: ...Table 1 Technical data...

Page 5: ...0 4 2 EN 61000 4 3 EN 61000 4 4 EN 61000 4 5 EN 61000 4 6 EN 61000 4 11 according to directive 2014 30 EU elektromagnetic compatibiltiy EN 60950 1 2006 in accordance with Directive 2014 35 EU Low Volt...

Page 6: ...by qualified customer service This devise is not waterproof To avoid the risk of electric shock protect the device from dripping water splashing water rain and moisture Do not place any fire source on...

Page 7: ...na 2 Network connection LED status green processor in use yellow network connected 3 Power supply connection socket 4 Slot for SD card The following accessories are included in the scope of delivery 1...

Page 8: ...mware 2 12 Activate communication to scales permanently By entering the scale number in the INI file a permanent connection is established independent of the configuration of the network interface A s...

Page 9: ...187 A basic understanding of the IP UDP or TCP protocol is assumed Several commands can be lined up in a data record separated by semicolon Only the last command may generate a feedback For example se...

Page 10: ...s activated which guarantees connection security An automatic timeout of 120 seconds is stored for the TCP protocol When the TCP protocol is activated connection security is guaranteed An automatic ti...

Page 11: ...01 16 No feedback This command is only available with active communication with the scale see F8 page 13 Alternatively a scale can also be activated automatically by means of INI file parameter ACT se...

Page 12: ...i iii iii iii IP address c Block check character E1 Error Alibi memory full E2 Error no standstil overload negative weight etc E4 Error Communication with scale is interrupted or scale is not connecte...

Page 13: ...angeover may only be carried out once for initialization of the Net Scale module If the channel change is permanently combined with other commands the function of the unit is significantly restricted...

Page 14: ...dd ssttttt ee c x Status byte 00 Stability indication 03 tared 04 Weighing range 06 always active f Errorcode 10 Overload 11 Test 14 battery empty 16 always active ss Space nnnnn Measured value 5 digi...

Page 15: ...02 01 00 ASCII Binary 0 1 0 0 0 0 0 0 Stability indication no Tare no Weighing range Range 1 corresponds to 0 17 16 15 14 13 12 11 10 ASCII Binary 0 1 0 0 0 0 0 1 A Stability indication no Tare no Wei...

Page 16: ...h an blockcheck character This block check character is formed by exclusive OR nexus of all characters of the data set and then OR with 0x40 When receiving such a secured data set the integrity of the...

Page 17: ...h digit of weight indication e g 10320 kg 6 Digit 3 3rd digit of weight indication e g 10320 kg 7 Digit 2 5nd digit of weight indication e g 10320 kg 8 Digit 1 1st digit of weight indication e g 10320...

Page 18: ...Sign always plus 19 Digit 5 5th digit of Tare 20 Digit 4 4th digit of Tare 21 Digit 3 3rd digit of Tare 22 Digit 2 2nd digit of Tare 23 Digit 1 1st digit of Tare 24 x Checksum 25 x Checksum 28 03 H En...

Page 19: ...the scale This can be changed in scale setup menue see chapter Change frequency and scale number 00 01 433 075 15 434 000 02 433 125 16 434 075 03 433 175 17 434 150 04 433 225 18 434 225 05 433 275...

Page 20: ...By pressing the TEST Button the crane scale display shows the current setting parameter in following sequences Parameter No 4 and No 5 are relevant Table 6 Parameter settings To change the scale and...

Page 21: ...ess the TEST key until P14 appears in the display Parameter P14 is used to set the scale number Press the TARE key to activate the parameter Then use the TEST key to select a desired value between 01...

Page 22: ...ashes several times on the display This indicates that the parameter change has been successfully stored To exit the SETUP menu press the Power On and Power Off buttons simultaneously or interrupt the...

Page 23: ...ou are familiar with the setting changes In the event of an error it may no longer be possible to reach the net scale via the network The demo tool automatically finds all available device blocks in t...

Page 24: ...emory Read measured value Reads the value from scale and writes it to the response field Registration network Reads the measured value and stores a data record in the verifiable memory Registration ma...

Page 25: ...SD card Data is transfered via ftp to your PC and stored in installation folder of Scale 99 Software Ensure that port 21 is available for ftp communication at your network The file S99_mem exe can be...

Page 26: ...folder of Scale 99 Cancel Cancels the action Print Prints the contents of the alibi memory Month Selection of month for the long term memory Year Selection of year for the long term memory Long term...

Page 27: ...nds of the weight 25 Digit 3 Hundreds of the weight 28 Digit 2 Tens of the weight 29 Digit 1 Unit of the weight 30 k k 31 g g 32 Blank 20H or 0 33 free space HEX20 34 Blank 20H or 0 free space HEX20 3...

Page 28: ...erated outside the radio link switched off or if the checksum of the scales dataset has an error The latter happens quite often if the radio link is disturbed by a different radio link or atmospheric...

Page 29: ...Do you need our support No problem just call us free of charge Reach our technical experts from Monday to Thursday between 8 am 4 pm CET and Friday between 8 am 12 am CET...

Page 30: ......

Reviews: