12
. . . Filter performance has greatly deteriorated
Cause
Solution
Safety adapter lever position not correct.
Check lever setting and adjust.
Safety adapter soiled.
Remove safety adapter; open shut-off lever and clean openings
with EHEIM cleaning brush (no. 4005570).
Hose installation.
Check that there are no kinks or marked narrowing of cross-section.
Hose installation soiled.
Clean hose installation with universal cleaning brush (no. 4005570).
Strainer blocked.
Remove coarse dirt, clean strainer.
Filter media heavily soiled.
Clean filter media.
Filter media filled into a net bag.
Never put long-term filter media in net bags or nylon stockings. This
leads to a drastic reduction in pump performance within a short time.
Filter media not cleaned properly.
When cleaning, remove the filter media from the filter media basket
and rinse through with lukewarm water.
Filter media wrongly assembled.
Check that filter media have been assembled correctly in the recom-
mended layers of filtering. Fill bottom filter insert to just under edge
with EHEIM MECH. Fill next filter inserts with EHEIM SUBSTRAT, also
to just under edge. Never place white filter pad under the handle.
Filter pad not renewed.
Be sure to renew the filter pad each time you clean.
Pump is dirty.
Clean pump chamber, cooling and lubrication channel with EHEIM
cleaning brush set (no. 4009560).
Water is not circulating properly.
Take filter into operation by priming (as described in the instructions).
Make sure that the water runback (delivery side) is above the surface
of the water during filling so that air is optionally bled from the device.
Too many accessories installed
Connected accessories reduce filter performance. Check and remove
on the hose system.
unnecessary accessories or operate via a separate water system.
. . . Pump does not work
Cause
Solution
No mains supply.
Plug in to mains.
Shaft broken.
Renew shaft (see list of spares).
Impeller missing or blocked by bits
Fit impeller, clean pump chamber.
of gravel, shells or similar.
. . . Air in the filter
Cause
Solution
Cause
Solution
Prefilter flap in prefilter
Check the prefilter flap for pollution and, if required, clean it.
not closed.
The prefilter flap must be unobstructed (see chapter 7.2, step 13).
Prefilter is filled with water.
Empty prefilter, repeat priming. Priming only works with empty prefilter.
Check valve polluted / defective.
Clean and, if required, replace the check valve (see chapter 7.3).
Summary of Contents for professionel4+ 250
Page 2: ...I...
Page 3: ...professionel 4e 350 Typ 2274 II...
Page 4: ......
Page 5: ......
Page 6: ......
Page 7: ......
Page 8: ...2271 2273 2274 2275 2371 2373...
Page 122: ...114 EHEIM 4001000 7 2 13 7 3 4005570 4005570...
Page 123: ...115 EHEIM SUBSTRAT pro EHEIM SUBSTRAT pro 2616805 4009560 10 EHEIM SUBSTRAT pro...
Page 128: ...120 8 EHEIM 4001000 7 2 13 7 3 EHEIM 4005570 EHEIM 4005570...
Page 129: ...121 7 3 9 EHEIM 4009560 3 10cm professionel 4e 350 2274...