8
For indoor use only. For use with aquariums. The aquarium filter is for domestic use only.
All electrical equipment in the water must be disconnected from the mains during care and maintenance work. To protect against
contact voltage being too high, the fixture must have a residual current device with a rated release fault current not exceeding 30 mA.
Ask your electrician.
The connecting line of this device can not be replaced. In case of damage to the power cord, the device is to be scrapped. Never carry
the pump by the cable; do not bend the cable.
This equipment can be used by children above the age of 8 or by persons with reduced physical, mental or sensory capacities or a
lack of experience or knowledge, provided they are supervised or have received instruction in the safe use of the equipment and the-
refore understand the risks involved. Do not allow children to play with this equipment. Do not allow children to clean or conduct user
maintenance without supervision.
Notice: These devices produce magnetic fields which might cause electronic and mechanical disturbances or damages.
This also refers to pacemakers. Please consult the manuals of medical equipment for the required safety margins.
Attention: Maintenance work presents the risk of crushing th fingers due to high magnetic forces.
For your own safety, we recommend to form a drip loop with the connection cable to prevent any water running
along the cable from intruding into the socket. When using a multiple socket or an external power supply unit,
position them atop the filter’s power connection.
Since a wide variety of varnishes and polishes are used when processing timer, the appliance feet can leave
visible traces on furniture or parquet floors as a result of chemical reactions. Therefore the device should not
be placed on unprotected wooden surfaces.
To achieve optimal operational safety there must be a maximum of 180 cm between the surface of the water
and the bottom of the filter.
Attention: Filter must always be operated in an uprigt position only.
Only thermofilter: Only suitable for sweet water aquariums. Protect the electronic system against water.
If an external mains cord or mains adapter is damaged, they must always be replaced. Contact your speciali-
sed dealer or your EHEIM Service Centre.
Burning danger! Be careful when touching the heating coil of devices with integrated heater.
Take the necessary precautions when handling components that can discharge static electricity.
Do not clean the unit – or parts of it – in the dishwater. Not dishwater resistant!
Do not dispose of this product as normal household waste. Take it to your local refuse collection side.
The product is qualified in accordance with the respective national regulations and guidelines and meets EC standards.
2.
Component overview (see II)
20 cm
max.
180 cm
1.
Filter mat blue
2.
Prefilter seal
3.
Prefilter flap
4.
Prefilter
5.
Cover grating
6.
Filter pad white
7.
Filter
inserts
8.
Locking clips
9.
Filter tank
10.
Rubber buffers
11.
Hose locking device
12.
Locking lever
13.
Safety
adapter
14.
Bracket
15.
Float
16.
Suction aid
17.
Pump head
18.
Range Xtender knob
19.
Adapter bar
20.
Control panel (
professionel 4e
+
- Typ 2274)
21.
Profile seal
22.
Pump wheel
23.
Pump cover
24.
Hoses
25.
Outlet elbow
26.
Nozzle pipe
27.
Suction pipe
28.
Sucker with terminal clamp
29.
Suction basket
30.
Power
supply unit (
professionel 4e
+
- Typ 2274)
31.
Power cable
32.
Connector socket for
EHEIM Interface
(optional)
Only thermofilter: 33.
Control indicator („ON“ / „OFF“)
34.
LED indicator in Celsius (°C)
35.
Status indicator for
target temperature in Celsius (°C)
36.
Pushbutton
37.
Display in Fahrenheit (°F)
38.
Heating spiral.
1.
Set the locking lever (12) to
„OFF“
and press the adapter bar (19) until the safety adapter (13) disengages.
2.
Open the locking clips (8)by pulling the clips’ lower edge.
3.
Remove the pump head (17).
4.
Remove all
inserts (7).
Caution:
Do not overfill filter inserts as, otherwise, their accurate fit is no longer assured.
5.
Fill the
filter inserts with EHEIM filter media.
6.
Rinse the filled filter inserts with water.
Note:
Easier cleaning with EASY CLEAN function.
7.
Close the filled filter cartridge with the screened cover (5).
8.
Shake filter insert. Repeat this procedure
3.
Connection and commissioning
Summary of Contents for professionel4+ 250
Page 2: ...I...
Page 3: ...professionel 4e 350 Typ 2274 II...
Page 4: ......
Page 5: ......
Page 6: ......
Page 7: ......
Page 8: ...2271 2273 2274 2275 2371 2373...
Page 122: ...114 EHEIM 4001000 7 2 13 7 3 4005570 4005570...
Page 123: ...115 EHEIM SUBSTRAT pro EHEIM SUBSTRAT pro 2616805 4009560 10 EHEIM SUBSTRAT pro...
Page 128: ...120 8 EHEIM 4001000 7 2 13 7 3 EHEIM 4005570 EHEIM 4005570...
Page 129: ...121 7 3 9 EHEIM 4009560 3 10cm professionel 4e 350 2274...