Operation Instructions
DSR Wif
i
Installation of Power Meter
The power meter should be connected to a spare 6 amp Mcb or Rcbo within the properties Consumer Unit. This supply
should then be taken and connected to a fused switched spur with a minimum contact of 3mm and fuse rated to
3amps. From the fused spur take a supply cable to the Power Meter that should be mounted within a mini
enclosure. Live and Neutral connections are cleatly marked at the bottom of the device.
(Take care not to damage the Terminals when connecting the power cable to the Meter)
Typical Layout:
TEST
6
3A
FUSE
Consumer Unit
Main Cable to Property
Earth not shown for clarity
Fused Spur
Mini Enclosure
Pairing the Power Meter
You can simply pair the power meter in the same way as you would a heater by putting the gateway into Pairing
Mode. Once the Gateway has been activated and is in the Pairing Mode, press the small button on the front of the
power meter for 3 seconds until it can be seen in the App.
The power meter will now begin recording the total amount of electricity used in the property, you can also set the
maximum usable power avalable to protect the incoming supply preventing overlaoding of the system.