RCL-CXXW_EHC_Rev.0_05-12-2018
15
/
26
Note
:
Advanced settings should only ever be changed by a fully qualified
engineer or with advice from EHC.
5.0 Advanced Engineer Settings
To enter advance settings
1.
Press the Config button once to show screen 1
2.
Now press and hold the Config button for 5 seconds, C1 will now appear
3.
Change Configuration Number by pressing the
+
or
-
buttons, then press
OK
4.
Change the Configuration by pressing the + or - button, Then
OK
to save.
1.
2.
Configuration Settings
C1: Temperature unit adjustment ºF/ ºC
C2: Heating control type adjustment
(Factory Set Do Not Change)
C3: Temperature compensation adjustment
C4: Firmware version
C5: Open window detection.
(Stops the heating for 30min if a fall of 2.4ºC is detected over a period of 4 minutes)
C6 Adaptive Control.
(This feature will turn the heating on early to meet the chosen temperature at the chosen time)
C7 Full or Manual control mode.
(Full Program or Basic Thermostat)
Controller User Defaults
Mode: OFF
Tª comfort: 19ºC
Tª eco: 17ºC
Tª frost: 5ºC
Tª mode manual: 19ºC
Temperature compensation Offset: 0ºC
RF link: No
Temperature units: ºC
Open window detection: OFF
Control mode: Factory Set Do Not Change
Program: All hours Eco