35
Control console 1202. Advanced functions
1202
1
Giving a number to each zone
This is the first thing that has to be done
in order to configure a system (and it
does not have to be done again if the
system configuration is not modified).
Provided that no groups have been
created yet:
SETUP
If the general access password is
NOT
active and there is NEITHER a pre-
recorded message player (1103) NOR
a module for sending messages over
the telephone (1104) in the system:
ZONES
ZONE SET
cancels all the numbers that
have been given to the zones until pressed
.
+
HERE
gives to the control console 1202 the
zone number 1 (the console needs a zone number
only if it must be ready to receive messages).
ZONE SET
When pressed, the system is ready
to assign number 1 to a zone, and all the
"zone set"
led lamps of the devices which can be given a zone
number will blink. If, in the mentioned devices,
one of the
ZONE SET
buttons is pressed, that
specific device will be identified as
ZONE NR. 1
,
and the system will get ready to assign number 2
to the following device / zone.
By following this procedure we can give
consecutive numbers to all the zones of the
installation without going back to the console
1202 (this is useful for the initial configuration of
the installation).
It is also possible to select a specific zone number
by pressing
+
or
–
and, after pressing
ZONE SET
and following the
ZONE SET
button of
the corresponding device, the selected number
will be given to that device (this is useful to replace
an old device by a new one which must have the
same zone number without repeating the set up
procedure).
When a zone number has been assigned to all the
zones of the installation, we will quit the labelling
procedure and all the
ZONE SET
led lamps of the
different devices will stop blinking.
Now it is recommended to start up the system
(point nr. 13) prior to label the zones with names.
2
Labelling the zones with names
If NO groups have been created yet:
GENERAL
(And the sign " < " appears next
to
GENERAL) +
ZONE
If three zones -for instance- have been
previously created:
ZON 001
(And the sign " < " appears next
to
ZON 001
)
+
If the general access password is NOT active
NAME
>>>
(the cursor is placed in letter
"O") +
+ ("O"
is replaced by
"P") +
3
Creating a group and giving it a number
If NO groups have been created yet:
GENERAL
(And then the sign “<”
appears next to
GENERAL
)
+
If the general access password is NOT
active:
NEW
YES
If the general access password is active the system will require us to introduce it every time we
try to operate one of the advanced functions (see point 2 of “access restrictions”).
Summary of Contents for Millennium 1105
Page 26: ......