ATTENTION:
The components A and B have to be connected according to the print-
ing on the unit and the applied color marking. Perforate bottom of container with
sharp-pointed object in order to let air come in when producing. Turn on the unit at
the operation button. Put a reception bowl under the mixing head and press push-
button. Keep the push-button pressed until the test silicone has been produced
completely and both components come out homogeneoulsy at the mixing head.
The egger ESG 2 is now ready to operate. Put negative form under the opening of
the mixing canula and press push-button or foot-operated switch. As long as the ma-
terial is not cured in the mixing canula (approx. 4 minutes) several gaskets can be
filled in succession. After having finished the filling process do not remove the mixing
canula. Do only remove the mixing before the next duplication by means of a 90°
turn to the right.
ATTENTION: Never produce against a mixing canula with cured material!
5.3 Change of bottles/cans
Remove the quick-coupling/bottle adaptor from the unit by means of tearing up-
wards the lock-up. Screw quick-coupling/bottle adaptor onto the new bottles/cans
and connect as described above. Observe the correct coordination of the compo-
nents according to the color.
Observe the contents of the containers at any time! They must not be emptied com-
pletely, as otherwise air gets into the system and the unit has to be deaerated under
great effort. A minimal filling of 2 - 3 cm has to remain in the cans.
6 Care and maintenance
Disconnect the unit from mains supply before care and maintenance!
Cleaning is effected with a mild cleaning liquid.
Wipe away silicone remainders from the unit. Keep coupling plug and mixing head
clean. The cleaning liquid must not get into the unit.
Repairs on the egger ESG 2 may only be executed by experts. Disconnect the unit
from mains supply at any rate.
Egger company is only responsible for the safety, reliability and performance of the
unit, if
- the unit is exclusively used for the corresponding field of application.
- operation is only carried out by personnel trained accordingly.
- the unit is operated in accordance with these working instructions.
- extensions, new adjustments, changes or repairs are executed by persons author-
ised by the company.
As we are currently developing our products, we reserve the right for technical
changes.
7 Service / Customer service
The manufacturer gives a device warranty of 24 months starting from the date of
purchase. For weat and tear parts (e. g. tooth wheels, etc.) and modifictaions on the
device as well we grant a guarantee of 6 months, corresponding to the German Citi-
zen’s Copde of Law § 477.
NOTE:
In case of improper handling of the egger ESG 2 all warranty and liability
claims will become extinct!
Page 11 of 16
Summary of Contents for ESG 2
Page 13: ...Seite 13 von 16 Page 13 of 16...