9
eltric K. Heckel GmbH
Weiherstraße 29
D-95448 Bayreuth
www.eltric.com
eltric K. Heckel GmbH
Weiherstraße 29
D-95448 Bayreuth
www.eltric.com
D
D
EN
EN
NL
NL
Note!
This feature is turned off by default and can only be changed when you press the button during
settings view.
During activation of this setting, only a standby dim time of indefinite time is possible.
See image 02 for clarification of this function.
Difference between Daylight sensor mode and corridor mode
The difference lies in turning on and off. In the corridor mode, the sensor will trigger (turn on) the
product whenever motion is detected, while in the daylight sensor mode the amount of light deter-
mines when to trigger the product. In the daylight sensor Mode, the product will therefore turn on
when it gets dark, even though there is no movement detection. See image 03 and 04 for a graphic
explaining the difference.
Light switches off automatically
after the stand-by period
elapses.
Daylight sensor fuction (img.04)
OFF
DIM
100% ON
POWER ON
CHECK
EVERY 30min
NO MOTION
MOTION
HOLD-TIME ENDS
Daylight sensor fuction (img.03)
Settings on this demonstration:
Hold-time: 30min,
Daylight sensor turn on threshhold: 50lux
Stand-by Dim: 10%
Stand-by period: +
∞
Daylight sensor turn off threshhold: 300lux
(when the Daylight sensor is activated,
the stand-by time is
∞
)
3
1
night time cycle
100% on when
motion is
detected, and
dims to 10% during
absence.
The light automati-
cally turns on at 10%
when natural light is
insuffcient (regardless
of motion).
When the natural
light-level exceeds
the set lux-value, the
light will turn off (re-
gardless of motion)
The light switches on
at 100% when there is
movement detected.
when motion is no
longer detected, the
light dims to the set
stand-by level after
the set hold-time
expires
The light remains on
at the set dim-level
during the night.
1
21:00
2
21:10
3
21:40
4
08:10
5
17:40
MODE SETTINGS (img.05)
Pre-programmed settings (modes 1 through 4)
The remote control has 4 pre-programmed settings available which can be sent directly to the sen-
sor. Below the schedule (see Img.05 with the default settings.)
By pressing 1 of the 4 mode buttons, you activate the corresponding mode with programmed set-
tings. These settings can then be sent directly to the sensor(s) with the <send> button.
The saved settings can be changed as desired by following step 2/3 of “ Change sensor settings “.
After that, these settings are stored under the relevant mode button.
APPLICATION
MODE
BRIGHTNESS
SENSITIVITY
HOLD TIME
STAND-BY
TIME
STAND-BY
DIM
DAYLIGHT
SENSOR
INDOOR
MODE1
100%
75%
5min
30min
30%
INDOOR
MODE2
100%
75%
1min
∞
min
30%
INDOOR
MODE3
100%
75%
5min
30min
30%
30LUX
OUTDOOR
MODE4
100%
75%
1min
∞
min
30%
(30LUX/300LUX)
2400340_1EGB_Manual_200929_EGB_683_625 - Complete Book A5.indb 9
29-9-2020 14:14:44