6
SMS Mode
3. Notification about low battery voltage
Before using this alarm the trigger voltage has to be set
using the
“setvolt”
command.
“setvolt”
: When the battery voltage drops below this
value the GSM-2-SMS modem sends an alarm SMS
message (default value is 0.0).
Example:
12345:setvolt:11.8
Set low voltage alarm trigger to 11.8 Volt (use decimal
point)
“addvolt”
: add alarm recipient
Example:
12345:addvolt:0170123333
Activate „low voltage“ message to phone number
0170123333
“delvolt”
: add alarm recipient
Example:
12345:delvolt:0170123333
Deactivate „low voltage“ message to phone number
0170123333
4. Master alarm (all alarms)
The
„addall“
command will send an alarm message to
the defined recipients if any of the 3 alarm types occur.
“addall”
: add master alarm recipient
Example:
12345:addall:0170123333
Activate to send “all alarms “to phone number
0170123333
“delall”
: delete master alarm recipient
Example:
12345:delall:0170123333
Deactivate to send “all alarms “to phone number
0170123333
5. Switch back to default settings
„default“
: switch back to default settings.
Example:
12345:default:
All alarm recipients will be deleted and no alarms will be
sent
Reset of EFOY-PRO:
EFOY-PRO status request via SMS
You can request the actual status of the EFOY-
PRO fuel cell via the following command.
Example:
12345:sfc:sfc – the GSM-2-SMS will return the
current status of the EFOY-PRO fuel cell via
SMS to your mobile phone.
Example:
SFC>SFC
battery voltage: 12.08V
output current: 0.0A
operating time: 5.8h
operating state: error
operating mode: auto
please change fuel cartridge
cartridge level below sensor
SFC>
Modem connection with EFOY-PRO fuel
cell:
The GSM-2-SMS modem offers a direct
connection to the data interface of the EFOY-
PRO device using a standard terminal
program such as Hyper Terminal.
Establish a dial up connection between the
GSM-2-SMS modem and your PC modem.
Use communication settings 9600 bits/s,
8bits/byte, 1 stop bit, no parity, no flow control.
Example:
ATD016045678
After a successful connection with the GSM-2-
SMS modem (
“CONNECT…”
) please enter the
last 5 digits of the GSM-2 IMEI number.
In case the authorization has been successful
“ok“
will be prompted and a direct
communication link has been established with
the serial data communication interface of the
EFOY-PRO unit (see more details in the
computer interface adapter manual).
In case the authorization fails
“bye“
will be
prompted and the connection is cancelled by
the GSM-2-SMS modem.