7.8.6.1 Setting the Speed Limitation Depending on High Lift
N
OTE
The setting of the speed limitation depending on high lift is necessary compelling by application of a new or a
new formatted top part detection module (OTE module).
Otherwise the machine speed limitation depending on high lift set with parameter
117
is in effect.
Besides, in the display of the operating device the tip is indicated
– Poti – .
Every mechanical change of the potentiometer
likewise requires this setting.
Parameter
501
is used to program the value for the minimum lift, and
502
for the maximum lift.
Proceed as follows:
Set the handwheel for a high lift for walking foot of 0 (minimum lift)
Select parameter 501! Set the handwheel for a high
lift for walking foot of 5 (minimum lift)
1x
E
Potentiometer value currently 112, with 110 stored
F-501 112 110
1x
+
Potentiometer value 112 taken
F-501 112 112
Set the handwheel for a high lift for walking foot of 5
(maximum lift)
1x
E
Next parameter displayed: potentiometer value
currently 120, with 118 stored
F-502 120 118
1x
+
Potentiometer value 120 taken
F-502 120 120
1x
E
Next parameter is displayed. Speed Limitation Depending
on High Lift (0 0 deactivated, 1 = activated
F-503 Pot 1
or
2x
P
P
End of programming
3500
PF321A
7.9 Speed Limitation n9
Function
with
or
without
control panel
Parameter
Speed Limitation n9
(n9)
122
When a key is pushed to which input function
33
is assigned, speed limitation n9 is activated. The speed is
controlled by the pedal up to the limit.
7.10 Speed Limitation n11 with Signal Output M10 / flip flop 2)
Function
with
or
without
control panel
Parameter
Speed limitation n11
Disabling of flip-flop functions at the seam end On/Off
Function "speed limitation n11" inverted/non-inverted
Function of signal M10 on socket ST2/29 after “power on”
(n11)
(FFm)
(FFi)
(FFo)
123
183
186
187
The speed limitation can be switched on by pressing a key on any of the inputs in1...i10 and switched off by
pressing the key again. A signal output which can be programmed individually (inverted/non-inverted) is
provided for the speed limitation. Furthermore, the function of signal output M10 can be determined after "power
on".
Summary of Contents for DC 1550