25
24
effigis.com
CPAT FLEX
User Manual (ARD4)
CPAT FLEX
User Manual (ARD4)
4.1.1 Electrical Installation
The ARD4 uses two connexions to the power, a fused connexion to the car battery (12 VDC)
and a connexion to the accessory circuit (switched 12VDC). This dual power connexion al-
lows the ARD4 to complete its operations when the vehicle is shut down. After all recording
and data transfer are completed, the ARD4 shuts itself off. When the switch is closed, the
green LED flashes to indicate that the ARD4 is in the closing process.
CAUTION!
We recommend that the poweer cable be installed by qualified personnel.
//
Rear panel (From left to right)
-
DRV
(DRV4 connector)
-
COM
(Expansion for future modules)
-
ITX
(Ingress transmitter module version 1)
-
12 VDC
(4 Pins Molex connector)
-
Wireless Antenna
(SMA)
-
GPS Antenna
(SMA)
Power Connections
Black (Ground)
To vehicule ground (metal body).
Red (Unswitched 12 VDC)
To 12 VDC electric terminal not controlled by ignition switch.
Green (Switched 12 VDC)
To 12 VDC electric terminal controlled by ignition switch.
Do not to use an intermittent accessory power like heating system
CAUTION!
The ARD4 must be installed on a 12V elecrtic terminal with an inline fuse
installed (5 Amp).
CAUTION!
Do not disconnect or modify vehicule security systems as airbags or seatbelts.
Security systems wires use only yellow sleeves and yellow connectors.