MINAC Systems
Revision A
USER MANUAL
31 January 2005
63860.doc
© For reproduction rights, see cover page.
Page 5
3
RESTRICTIONS IN USE
Only use the MINAC solely for its intended purposes under safe conditions and in
proper surroundings. Take great care when using the equipment. Heat only electrical
conductive materials. The presence of combustible materials involves a risk of fire.
The MINAC systems provide the following output power limitations for continuous
use and intermittent duty:
Equipment
Continuous use
Intermittent duty
MINAC 25, 25 Twin
25 kW
40 kW
MINAC 50/80
50 kW
80 kW
The maximum output powers are attainable only with low Q - magnetic steel. The
maximum duty factor is 0.5 and the maximum cycle time is 10 minutes. This means
that during a selected cycle, the unit can run at maximum output power only half of
the time (to a maximum of five minutes).