14. SELECT SEGMENT TYPE
Press F2 if "STEP" is not already set as the segment type.
15. SELECT TIME UNIT
Press F3 until "1 m" is displayed.
16. ENTER NUMBER OF TIME UNITS
Enter the number 4.
<4> and <
↵
>
17. SET TARGET SETPOINT
Move the cursor down a line by pressing the down arrow key and enter the
number 30.
<
↓
>, <30> and <
↵
>.
18. SELECT SEGMENT NO 3
Press F1 and the number 3 is displayed.
19. SELECT SEGMENT TYPE
Press F2 if "RAMP" is not already set as the segment type.
20. SELECT TIME UNIT
Press F3 until "1 m" is displayed.
21. ENTER NUMBER OF TIME UNITS
Enter the number 3.
<3> and <
↵
>
22. SET TARGET SETPOINT
Move the cursor down a line by pressing the down arrow key and enter the
number 0.
<
↓
>, <0> and <
↵
>
23. PROGRAMMING SEGMENT NO 4-9
This heating sequence (Sequence A) consists of just four segments. This
means that the remaining six segments in the program must be set to zero
duration. Proceed as follows:
a)
Select segment no (4-9).
b)
Move the cursor to the "Time" line by using the down arrow key,
↓
.
c)
Enter the number 0, <0> and <
↵
>.
The sequence is now programmed and ready to run, provided that the "SEQUENCE"
function in the Activate Menu (menu 2) is activated.