MINAC Systems
Revision A
USER MANUAL
31 January 2005
63860.doc
© For reproduction rights, see cover page.
Page 26
• Sequence
• Timer
• Water Auto Shut-off
• Energy Supervision
• PIN Code
• Language
• Extended Operating Range
The sequence and timer functions are mutually exclusive. For further information
about the control functions, refer to paragraphs 5.2.1 and 6.3.2.
a. Go to the Activate Menu (F0 in the Main Menu).
b. Activate the desired control functions by pressing the keys in front of the
various options (sequence and timer are mutually exclusive functions).
c. Return to the Main Menu (press F9).
2.
Choose Mode of Operation (Setpoint Menu)
There are three modes of operation: AC current, DC power and Temperature
(mutually exclusive functions). The selected mode of operation regulates the
output power determined by a given setpoint. For further information about
modes of operation and the reference setpoint, refer to paragraphs 5.2.4 and
6.3.3. Temperature operation requires additional temperature measuring
equipment.
a. Go to the Setpoint Menu (F1 in the Main Menu).
b. Choose the mode of operation.
c. Return to the Main Menu (press F9).
6.2.3
Power on
1.
Setpoint Source
The setpoint source is determined in the Setpoint Menu (menu 3). Function F3
"Setpoint source" gives the following options:
LOC
Setpoint from the “up” and “down” arrow buttons on the control panel.
EXT
Setpoint from an ECU or other external device.
HHT
Setpoint from the setpoint control on the HHT handle if available.
DEFAULT
Setpoint from the source where power on command was detected.