Digital Time, Air Pressure and
Vacuum Pressure LCD Display

• Programmable floating decimal provides time range

readout from 0.001 to 99.99 seconds.

• Air pressure readout can be programmed in either

psi or bar.

• Vacuum pressure readout is displayed by holding

the vacuum toggle switch in the "up" position.

Memory

Can store up to eight Time settings. (See page 20.)

Run/Setup

1. The 

RUN

 mode allows access to all eight cells. Cell

numbers are displayed as 

CEL1

,   

CEL2

...

.CEL8

. Chang-

ing the cell number will change the time setting corre-
sponding to that cell.
The 

SETUP

 mode provides access to selected cell

TEACH

 and 

TIME SET

 functions. Only in the 

SETUP

 mode

can cell time values be viewed, cleared, or changed.
2. In the 

RUN

 mode, the functions are inoperative.

Steady/Teach

In 

SETUP

 mode, pressing 

STEADY/TEACH

 will clear

the currently displayed cell setting, reset the cell
display to blinking "

0000

", and place the dispenser

in a 

TEACH

 mode (refer to page 12 for 

TEACH

procedures).

In 

RUN

 mode, pressing 

STEADY/TEACH

 will override the

timer and dispense for as long as the foot pedal is
pressed. The dispenser display will read "

----

" in the

STEADY 

mode.

Time Set

 

  ▼

 

(down)

    

 

(up)

In 

SETUP

 mode, use the 

TIME SET

 buttons to change

time settings. Left buttons scroll digits quickly; right
buttons scroll digits slowly.

Pressure/Time

Press to change display values from 

TIME

 to 

PRESSURE

or 

PRESSURE 

back to 

TIME

.

In 

SETUP

 mode, pressure readings may be changed

from PSI to BAR and BAR to PSI by pressing and
holding the 

PRESSURE/TIME

 button for four seconds.

STOP

This button stops the dispenser immediately.

Barrel Vacuum Contro

l

Refer to page 16 for operation.

Air Pressure Regulator

Refer to page 11 for operating  instructions.

STEADY

RUN

SETUP

CYCLE

STOP

Run

Setup

Fast

Slow

Time Set

Pressure

Time

Fast

Slow

Time Set

Pressure

Vacuum

Steady

Teach

Cell Select

E

L

1

  C

Vacuum

Pressure

®

A NORDSON COMPANY

2000XL

Function
Indicator
Lamps

Air pressure
regulator

Barrel vacuum
control

Vacuum
toggle switch

Features and Controls

Summary of Contents for 2000XL

Page 1: ...t Steady Teach Pressure Time Fast Slow Time Set Pressure Vacuum Vacuum Pressure A NORDSON COMPANY Operating Guide 2000XL Series Digital Dispensers A NORDSON COMPANY In the US 800 556 3484 In the UK 08...

Page 2: ...troduction The 2000XL Series dispensers provide years of trouble free productive service This Operating Guide will help you maximize the usefulness of your new dispenser Please spend a few minutes to...

Page 3: ...Vacuum Control 16 17 Loading the Barrel Reservoirs 18 19 Memory Function 20 21 Input and Output Connection Instructions 22 Schematic and Replacement Parts List 23 Troubleshooting 24 Suggestions and R...

Page 4: ...etermine the proper amount The microprocessor remembers the time and repeats this amount with each cycle until you are ready to change it From microdeposits to volumetric filling the 2000XL provides t...

Page 5: ...Model 2000XL CA is supplied with an EFD five micron filter regulator with coalescing filter 2000F756 Bottled nitrogen can be used Warning If high pressure bottled air or nitrogen is used a high pressu...

Page 6: ...e the dispenser in a TEACH mode refer to page 12 for TEACH procedures In RUN mode pressing STEADY TEACH will override the timer and dispense for as long as the foot pedal is pressed The dispenser disp...

Page 7: ...the upper right corner of the front panel are four indicator lamps These lamps indicate the mode of operation STEADY Indicates that the timing feature has been overridden and that the output is contro...

Page 8: ...it and position the correct voltage to show through the cartridge window Replace the cartridge into the power cord receptacle and insure that both sides snap securely into position Install the power...

Page 9: ...mesettingbyafactorof10 Forexample 5 35 seconds becomes 53 50 15 00 seconds becomes 1 50 Setting the pressure readout The dispenser is shipped with pressure display programmed in psi Note On models wit...

Page 10: ...si maximum to regulator Output from regulatorshouldbeaminimumof80psi maximum100psi For model 2000XL PR5 output from regulator should be set at 30 psi Check voltage label on dispenser Male quick connec...

Page 11: ...h knob in to lock Dispensers with air pressure gauges higher than 15 psi are tested using the nontoxic blue fluid supplied in the Dot Test kit This fluid is represen tative of thick non leveling fluid...

Page 12: ...s the total time for both deposits You can build up to the desired amount by simply pressing the foot pedal repetitively until the deposit is the proper size If the deposit becomes too large press STE...

Page 13: ...to be pressed mo mentarily The complete time cycle will run once the dispenser is initiated Press RUN SETUP and toggle back to the SETUP mode Press the TIME SET buttons and change the time to 2 30 se...

Page 14: ...oozing by responding to the pressure of trapped air with a slight suck back movement after the dispense cycle The white piston is used for most fluids However if you are applying RTV silicone and fin...

Page 15: ...id Maximum 1 2 fill If you use low to medium viscosity fluids the white SmoothFlow piston has several advantages First vacuum adjustment is much less sensitive Second the piston prevents fumes from th...

Page 16: ...TUP to return to RUN mode 5 Press STEADY TEACH STEADY indicator light on 6 With the barrel pointing downward over a container unsnap the safety clip and press the foot pedal to fill the tip 7 If a dro...

Page 17: ...ofthetip slowlyturnthevacuum control knob counterclockwise to stop the drop from growing Wipe the tip and adjust vacuum as necessary Now the fluid is in proper balance It does not bubble or drip Repea...

Page 18: ...acrylates or anaerobics use the LV Barrier Place barrier in the top of the barrel reservoir Allow air between barrier and fluid Do not contact the barrier to the fluid Ifyourfluidisthickornon leveling...

Page 19: ...ressure the barrel loader fills the barrel with piston from the bottom up If the fluid comes packed in a 1 10 gallon 300 ml caulking type cartridge use the EFD 940BL barrel loader 2 If you receive fro...

Page 20: ...review the contents of each cell before selecting and storing a new time setting into memory 1 Press RUN SETUP to place the dispenser in RUN mode RUN indicator light on The current cell number will b...

Page 21: ...cell contents 4 Enter the desired time setting by using the TIME SET button or the TEACH function and foot pedal refer to page 12 5 Press RUN SETUP to place the dispenser in RUN mode RUN indicator lig...

Page 22: ...e an open collector circuit closes and remains closed until the next dispense cycle This circuit can be utilized to signal back to a host computer start another device in sequence or other operations...

Page 23: ...085 1 8 NPT male 1 4 barb elbow low profile 13 2087 1 8 NPT male 1 4 barb elbow 14 2094 1 8 NPT male 1 16 barb 60 15 2024 160 Tubing 170 x 1 4 16 2009 A24 Power cord 17 7143 01 Output circuit fuses 18...

Page 24: ...to be sure air pressure is not varying 3 Air bubbles in the material can cause inconsistency For best results remove all air bubbles Timer seems inoperative Check to be sure STEADY mode is off Note T...

Page 25: ...con tamination and provides proper safety 3 Do not completely fill the barrel For most fluids optimum fill is a maximum 2 3 of the barrel capacity For cyanoacrylates or watery thin fluids optimum fill...

Page 26: ...ter assemblies Molded one piece yellow SnapLok adapter head with Buna N O ring flexible 5 32 O D hose male quick connect and safety clip size with 3 ft hose with 6 ft hose 3cc 1000Y5148 1000Y5148 6 5c...

Page 27: ...of purchase Within the period of this warranty EFD will repair or replace free of charge any defective component regardless of fault on return of the part or the complete dispenser prepaid to the fact...

Page 28: ...ability in the U S A Printed on recycled paper Unit 14 Apex Business Centre Boscombe Road Dunstable Bedfordshire LU5 4SB UK Freephone 0800 585733 From Ireland 00800 8272 9444 Telephone 01582 666334 Fa...

Reviews: