Schmid & Wezel
D-75433 Maulbronn
Page
4
4 of
5
8
Version 1
07.2012
6. Cleaning and Maintenance
Disconnect the unit from
the works mains before
any cleaning and
maintenance work!
Prior to starting any
maintenance, ensure that
the lids (B) are open
(safety lock-out) which
will prevent the unit from
being switched on
unintentionally!
6.1 Daily cleaning after
completion of the slaughter
Trouble-free, continuous operation can be
ensured only if the splitting saw is
permanently kept in a clean, hygienic
condition. The machine should normally be
disinfected before each cleaning.
Observe the applicable safety and hygiene
regulations (EN 1672)!
Disinfectants must not be allowed to come
into direct or indirect contact with
foodstuffs. Rinse the machine with clear
water after disinfection.
Do not use aggressive
solvents! Do not use
steam or high-pressure
cleaners! Do not immerse
the unit in water!
6.1.1 Disinfection
Disinfect the unit during operation after
every cut with hot water (82° C).
6.1.2 Cleaning the splitting saw
After work, slacken the saw belt (see
section 4.1.1 "Disassembling the saw belt"
(p 6)), re-move the saw belt, clean with hot
water and dry.
The same applies to the guide: remove
after every application and carefully clean
the entire drill hole for the holder (see
section 4.2 "Saw belt guide".
Use a cloth, brush and warm water (40 - 55
°C) to clean the unit. Stubborn or encrusted
dirt and residue must be soaked
beforehand. Clean using a cleaning agent,
preferably as a foam, that is applied to the
surface to be cleaned and allowed to work
in for 15 - 20 minutes. Subsequently wash
off the loosened dirt manually with warm
water.
Recommended cleaning agents
Diversey Lever Tego 2000:
Surface-active disinfectant.
Diversey Lever GmbH
Mallaufstr. 50-56, 68219 Mannheim
Alternatively:
P3-topax 91:
Surface-active disinfectant
Henkel-Ecolab Deutschland GmbH
Postfach 13 04 06, 40554
Düsseldorf
A cleaning plan and further details can be
obtained from the above company
addresses.
The above cleaning agents are only a
recommendation; if other cleaning agents
are used, the customer should examine the
material compatibility and the compliance
with the hygiene regulations.
6.1.3 Lubricants
Lubricants are subject to the regulations
applicable to the foodstuffs sector (DIN
1672).
Recommended lubricant for gearbox:
Klübersynth UH1 12-1600 (H1)
EFA special grease
Order No. 001 365 644 (0.8 kg)
Order No. 001 365 645 (5.0 kg)
Amount of grease requried for gearbox:
EFA SB 325 E: 2.0 - 2.5 kg
Grease recommended for all lubrication
points, guide and torque wrench:
Molykote Longterm W2
EFA special grease
Order No. 001 365 623 (1 kg)
Order No. 001 365 624 (5 kg)
Oil recommended for oil bath of torque
wrench:
Weissöl Shell-Ondina G17, 15 Centistok /
40°
Special oil:
Order No. 001 365 611 (0.5 l)
Order No. 001 365 612 (5.0 l)