Schmid & Wezel
D-75433 Maulbronn
Page
4
0 of
5
8
Version 1
07.2012
Fig. 8: Replacing the guide
(3)
Hold the guide at its top point (3)
Lift the lever up and out of the fixture (4)
Remove the lever from the rail (5)
Fig. 9: Replacing the guide (4)
Install the saw belt, see section "Assembling
the saw belt"
You have now uninstalled the fibre guide
(6) and lever (7)
You can now check both parts for wear and
replace worn parts as necessary!
Front rail
Take the same steps to disassemble the
front rail of the splitting saw for maintenance
purposes.
Fig. 10: Replacing the guide (5)
New gap: 0.6mm
(Max. gap: 2 mm)
Fig. 11: Replacing the guide (7)
3
4
Fixture
5
6
7