6. Saw cut frayed
Saw band guide mechanism worn
See chapter 4.2 "Saw band
guides" (page 6)
Strip (front or rear) holding the
guide worn out, so that the guide
is in an inclined position
Replace strip; always replace the
strips in pairs (front and left)!
The bolt of the suspension of
band saw is worn, causing the
saw to be suspended at an angle
Correct suspension or replace
bolt
Band positioned incorrectly, no
tooth set
Insert band so that the teeth face
the motor, see chapter 4.2 "Saw
band guides" (page 6)
Guide wheel at front or rear worn
Check wheels; replace, if
necessary
7. Band jumps from wheel
Guide wheel at front or rear worn
Check wheels; replace, if
necessary
Band tightening torque too low
Retighten band with the torque
wrench
Wheel ball bearings (front/rear)
worn out
Check bearing play; replace
bearings, if necessary
Frame misaligned
Cannot be repaired; purchase
new frame and remount
individual parts
8. No water during cleaning
(saw)
Connection of solenoid valve
loose
Check hose; replace, if necessary
Solenoid valve defective
Check valve; replace, if necessary
Nozzles or water pipe blocked by
limestone or dirt
Clean parts; replace, if necessary
9. No water during cleaning
(operation)
Water connection defective or
loose
Check hose; replace, if necessary
Water hose not connected or
supply system defective
Check and repair
Table 1: Troubleshooting splitting saw