INSTALLATION INSTRUCTIONS
Be sure to wire the Repeater into a 12V power source that will be "on" during
vehicle operation. The Repeater will be on as soon as it is connected to power.
The red light stays on when power is connected.
The center button that lights up also serves as a reset button.
Fuse-2A
( DC12~DC24V)
'"
-
- Hot Wire (+)Red
- - -
Ground Wire(-)Black
INSTALLATION OF THE REPEATER ONLY REQUIRES IT BEING CONNECTED TO A 12V
POWERSOURCEAND GROUND-WHEN THE RED LIGHT COMES ON IT IS FUNCTIONING.
(Tractor Trailer (Big Rigs) that do drop and pulls of multiple trailers you need to use
the next section on page 26 because it requires a link function.)
REPEATER/BOOSTER ALERTS
High/Low Pressure and Fast Leak Alerts
When the sensor detects high/low-pressure abnormalities and rapid leaks, it
will send an alert to the Repeater/Booster immediately. The audible alarm will
be on together with the flashing red light. Press the button on the transceiver
to turn off the alarm. However, the flashing red light will continue until the
problem is corrected. The system is set to alarm if you loose more than 7.25
psi in a minute.
High-Temperature Alert
The Repeater/Booster has a fixed temperature alarm at 194
°
F/90
°
C. The
sensors send the temperature readings to the Repeater. If the temperature
is above 194
°
F/90
°
C, an audible alarm will be on together with the flashing
red light. Press the button on the transceiver to turn off the alarm. However,
the flashing red light will continue until the temperature is dropped below
194
°
F/90
°
C.
- - - - - - - - - - - - - -
22 - - - - - - - - - - - - - -