Pin Assignment

3.5“ Display System

E.E.P.D. GmbH | Gewerbering 3 | 85258 Weichs

© 2016-2019 E.E.P.D. GmbH. All Rights Reserved

Pin Assignment X19

Pin

Signal

Description

1 THERM_SENSE_N Temperature Sensor

3 THERM_SENSE_P1

5 RS485_RX_P

Serial Interface 2

7 RS485_RX_N

9 RS232_TXD

Serial Interface 1

11 RS232_RTS_m

13 GPO_0

Open drain,
High max. Vin, 5mA

15 GPO_1

17 GND_IN

DC -

19 PVIN

DC +

Pin Assignment X18

Pin

Signal

Description

1 Relay 1 60VDC, 2A max, 

no fuse - input fuse necessary

2

3 Relay 2 60VDC, 2A max, 

no fuse - input fuse necessary

4

1

2

19 20

1

4

Pin Assignment X19

Pin

Signal

Description

2 THERM_SENSE_P2 Temperature Sensor

4 PWM_OUT

OD, High max. Vin, 5mA

6 RS485_TX_N

Serial Interface 2

8 RS485_TX_P

10 RS232_RXD

Serial Interface 1

12 RS232_CTS_m

14 GPI_0

Low max. 3V,
High max. Uin

16 GPI_1

18 CAN_P

High speed CAN,1Mb/s

20 CAN_N

X19

X18

1

2

20

19

1

4

Summary of Contents for Androx

Page 1: ...Operating Manual 3 5 Display System Copyright 2016 2019 E E P D GmbH All Rights Reserved...

Page 2: ...ked carefully and is believed to be reliable However E E P D GmbH gives no guarantee or warranty concerning the accuracy of spoken information and shall not be responsible for any loss or damage of an...

Page 3: ...he system and is not con sidered as assured characteristics The written declarations in this specification are not consti tuent part of any contract E E P D GmbH reserves the right to modify the infor...

Page 4: ...Terms of Business effective the date of the original shipment from E E P D GmbH In the event of a warranty claim for defects which appear within the warranty period custo mer shall deliver the product...

Page 5: ...e claim regardless of whether such claim is brought in breach of contract or warranty neg ligence strict liability or otherwise Reshipment If you return the ANDROX system to E E P D GmbH please remove...

Page 6: ...ferences 7 4 Safety Usage 8 5 Electric Connectors 9 6 Pin Assignments 10 7 General Operation Operating System 11 8 ANDROX with Android 12 9 Start up with Android 13 10 Create Android Application 14 11...

Page 7: ...of the ANDROX system in the columns operating elements and plug allocation The service of the ANDROX system is descri bed in the categories General information Connectors and pin assignment ANDROX wit...

Page 8: ...rks exclusively wit hin the given DC voltage range Repair work can only be performed by an au thorized certified specialist supplier or from the manufacturer customer service personel This is to be pa...

Page 9: ...N Ethernet 10 100 1000 Mbits s RJ45 3 USB 2 0 Type A female connector Host Port 4 microSD 2 0 Card Slot 2x 4 1 Slot 1 operating system 4 2 Slot 2 optional data 5 HDMI 1 4 6 No use 7 X19 IO connector f...

Page 10: ...rain High max Vin 5mA 15 GPO_1 17 GND_IN DC 19 PVIN DC Pin Assignment X18 Pin Signal Description 1 Relay 1 60VDC 2A max no fuse input fuse necessary 2 3 Relay 2 60VDC 2A max no fuse input fuse necessa...

Page 11: ...0 5 seconds to switch off push the button 5 seconds In the switched on state Default setting at de livery you can turn on off the system over the power supply If you turn off over power supply make s...

Page 12: ...r current state These include no gua rantee warranty and legal claims Create a bootable microSD Card for AndroidTM If you don t have the preloaded mSD card from E E P D it is necessary to installed th...

Page 13: ...stem AndroidTM 4 2 Now the mSD Card be used in the ANDROX system Prepare the ANDROX System Insert the mSD Card with operating system Android in the mSD Interface 1 To transfer applications on the ANDR...

Page 14: ...about stan dard Apps in the literature of AndroidTM 4 2 Other Apps are to be installed in the form of an APK because Google PlayTM is not on the system Also example Apps and own generated Apps can be...

Page 15: ...our PC Start Android Studio and select in the Wel come Window Import Non Android Studio Projekt Select and confirm the folder with the ex ample application AppThermometer on the microSD Card with OK C...

Page 16: ...h OK On your PC window Choose Device choo se ANDROX System and confirm with OK The example application AppThermometer is transferred on the ANDROX system and is installed Configuration Temperature Sen...

Page 17: ...D Card from E E P D it is necessary to installed the operating system on a mSD card Technical information for Yocto Linux can be requested from androx eepd de To install Yocto Linux on your mSD Card y...

Page 18: ...terface 1 Optional put in a second mSD Card for data and similar in the mSD connector 2 Optional plug in a LAN cable HDMI cable und USB cable Switch on the ANDROX System Supply the connectors 17 and 1...

Page 19: ...perature Sen sors The picture on the right shows connection va riations of the temperature sensors The plug allocation is described on the page 8 Turn off System To turn off the system switch off the...

Page 20: ...z Ethernet 10 100 1000 Mbit s Gbit Ethernet is li mited to maximum 480 MBit s USB 2 0 Type A female connector Host Port USB 2 0 Mini B female connector on the go Cli ent Port Serial Interface RS232 4...

Page 21: ...ence Gigabit Ethernet Ethernet connection with a transfer rate up to 1000Mbit s GND Chassis ground GPIO General purpose input output Host A network host or other device connected to a computer network...

Page 22: ...E E P D GmbH Gewerbering 3 85258 Weichs Copyright 2016 2019 E E P D GmbH All Rights Reserved This Page Intentionally Left Blank...

Page 23: ...E E P D GmbH Gewerbering 3 85258 Weichs Copyright 2016 2019 E E P D GmbH All Rights Reserved This Page Intentionally Left Blank...

Page 24: ...E E P D GmbH Gewerbering 3 85258 Weichs Copyright 2016 2019 E E P D GmbH All Rights Reserved...

Reviews: