5- ELECTRICAL INSTALLATION 

 
Eemax recommends that this product be installed by a licensed and qualified electrician in accordance with all 

applicable national, state, provincial, and local electrical codes. As with all electrical appliances, under no 
circumstances should you attempt to install, repair or disassemble this water heater without first shutting off all 
power to the unit directly at the fuse or breaker box. Make sure to shut off all breakers. SERIOUS BODILY INJURY OR 

DEATH COULD OCCUR IF YOU IGNORE THIS WARNING.

 

 
All wiring (wire gauge) and circuit protection (breakers) must comply with the U.S. National Electrical Code (NEC) 
in the U.S.A., or the Canadian Electrical Code (CEC) in Canada. Failure to do so could result in property damage 
and/or personal injury, and void your warranty. Note: the Canadian Electrical Code generally requires that all 
supply wires and corresponding circuit protection used for domestic hot water heating and hydronic heating 
applications be sized to a minimum of 125% of the maximum current rating of the heater (see model specifications 
below for details). 
 
Before installing this product, ensure that the home has sufficient electrical power available to handle the 
maximum amperage load of the applicable model. 

 

 
IMPORTANT NOTES: 

Model PR008240, PR011240, and PR013240 require 1 set of wires and ground 

(see wiring diagram)

 

Model PR018240 requires 2 sets of wires and ground 

(see wiring diagram) 

Model PR024240 and PR027240 require 3 sets of wires and ground 

(see wiring diagram) 

Model PR036240 requires 4 sets of wires and ground 

(see wiring diagram) 

Please see required wire gauge on the next page 
Each set of wires must be connected to its own individual double pole breaker 

 
 

Installation Instructions 

 
STEP 1: 

Take each wire pair and connect them to one breaker (see wiring diagram). Make sure that each breaker is 

connected with one black wire and one red wire

 

STEP 2: 

Using a suitable wire gauge that meets all applicable electrical codes for the size of the breakers used, run the 

correct sets of wire from the home’s main breaker panel to the tankless water heater.  

 

STEP 3: 

A separate ground conductor for each incoming circuit is required. 

STEP 4: 

DOUBLE CHECK the electrical connections to make sure they are correct and that all wire connections are tight 

and secure. Also confirm that the correct breaker size and wire gauge has been used and confirm that the unit has been 
connected to a ground in accordance with applicable codes. 

STEP 5: 

Confirm that all the air has been purged from the water lines prior to turning on power to the unit. Refer to 

STEP 2 in the plumbing installation section. 

 
 
 
CAUTION

: Ensure that you have made the correct connections. You must follow the wire connection as shown 

to ensure proper operation of the unit. If you mix up one set of wires with another, the unit will not operate 
correctly even though it turns on and otherwise appears to function properly. 

 

The water heater is now installed and ready to use! Follow the General Operating Instructions to complete the set 

up. We highly recommend that this is done with the homeowner present. 
 

 
 

Summary of Contents for PR008240

Page 1: ...aker box SERIOUS BODILY INJURY OR DEATH COULD OCCUR IF YOU IGNORE THIS WARNING THIS PRODUCT SHOULD BE INSTALLED BY A QUALIFIED ELECTRICIAN OR PLUMBER IN ACCORDANCE WITH ALL NATIONAL STATE PROVINCIAL AND LOCAL ELECTRICAL PLUMBING CODES PLEASE READ THESE INSTRUCTIONS THOROUGHLY AND COMPLETELY PRIOR TO INSTALLATION USE FAILURE TO DO SO COULD CAUSE PROPERTY DAMAGE SERIOUS INJURY OR DEATH This manual s...

Page 2: ......

Page 3: ...e any questions please contact us directly at Eemax Inc 400CaptainNevilleDrive Waterbury CT06705 Toll Free 1 800 543 6163 or 203 267 7890 Fax 203 267 7975 info eemaxinc com CONTENTS 1 BEFORE INSTALLATION 2 SELECTING A LOCATION TO INSTALL 3 MOUNTING YOUR WATER HEATER 4 PLUMBING INSTALLATION 5 ELECTRICAL INSTALLATION 6 SIZING GUIDE 7 GENERAL OPERATING INSTRUCTIONS 8 MAINTENANCE 9 TROUBLE SHOOTING GU...

Page 4: ...rical boxes or junctions If you plan to install your water heater on a second floor or in a heated attic space make sure that you follow all code requirements for such installations as required for your area We recommend that you install a drip pan connected to a safe drain below the water heater to avoid property damage in the unlikely event of a leak Alternatively you can install an active water...

Page 5: ...ons UL Standard 499 does NOT require that a pressure relief valve be used However a T P valve may be required to meet installation codes in your area If one is required install the pressure relief valve in accordance with local codes and ensure that it operates correctly and that air is purged from the valve prior to installing the water heater When connecting to Flex or High Temperature CPVC pipe...

Page 6: ...Model PR024240 and PR027240 require 3 sets of wires and ground seewiringdiagram Model PR036240 requires 4 sets of wires and ground seewiringdiagram Pleaseseerequiredwiregaugeonthenextpage Eachsetofwiresmustbeconnectedtoitsownindividualdoublepolebreaker InstallationInstructions STEP1 Takeeachwirepairandconnectthem toonebreaker seewiringdiagram Makesurethateachbreakeris connectedwithoneblackwireando...

Page 7: ... AMPS REQUIRED BREAKERS 1 x 40 AMP 1 x 50 AMP 1 X 60 AMP 2 X 40 AMP 3 x 40 AMP 3 X 40 AMP 4 X 40 AMP REQUIRED WIRE GAUGE 1 x 8 AWG 1 X 6 AWG 1 X 6 AWG 2 X 8 AWG 3 x 8 AWG 3 X 8 AWG 4 X 8 AWG Circuit Breaker 1 L1 L1 PR018240 requires 2 sets of breakers and wires PR024240 PR027240 require 3 sets of breakers and wires PR036240 requires 4 sets of breakers and wires PR008240 PR011240 PR013240 require 1...

Page 8: ...heater and limit the maximum volume coming out of your unit to a specified flow rate to prevent the exit temperature from becoming too cool To learn more about flow restrictors or find out how to purchase one for your tankless water heater visit us online at Eemax com or contact us at 1 800 543 6163 Steps for Choosing a Flow Restrictor 1 Find your model in the chart on the left 2 Choose the column...

Page 9: ... risk of a water leak we recommend the following maintenance You should inspect the connections on the inlet and outlet of the water heater at least on an annual basis for any signs of damage or failure Any signs of damage cracks leakage or weakness should be addressed Take care not to over tighten the connections Serious internal damage to your water heater can occur if you over tighten the water...

Page 10: ...ossible that the wiring is incorrect Voltage less than 240 volts The heating elements on your water heater are design for 240 volts When use with a lower voltage they produce less heating power You may need to upgrade to a larger model Mixing too much cold water You do not need to mix as much cold water with your tankless water heater compared to when you use a conventional water heater You may al...

Page 11: ...change the temperature set point exposes electrical shock and burn hazards which can cause INJURY or DEATH Adjustment should only be done by a licensed plumber or electrician PR008240 PR011240 PR013240 PR018240 PR024240 PR027240 PR036240 1 Hot Water Outlet 4 Temperature Set Point Display 6 Wire Connection 2 Cold Water Inlet Remove Cover to Access 7 Brass Compression Nut 3 Celsius Fahrenheit Conver...

Page 12: ...Eemax Inc 400CaptainNevilleDrive Waterbury CT06705 Toll Free 1 800 543 6163 or 203 267 7890 Fax 203 267 7975 info eemaxinc com ...

Reviews: