The following table represents some of the most common technical support questions we receive. Before calling us, 

please read thoroughly to see if your question or problem is addressed.

 

PROBLEM

 

POSSIBLE CAUSE

 

SOLUTION

 

Water heater is not heating at all (water is flowing 
but  the  unit  is  not  heating  at  all  —the  outgoing 
water  temperature  is  the  same  as  my  cold  water 
supply) - the digital display does NOT light up. 

No power or incorrect wiring. 

Make sure the breakers at main electrical panel are ON. You 
may have a faulty breaker or unit may be wired incorrect. 

Flow rate is too low / water pressure is too 
low. 

Your water heater has an activation flow rate of 
approximately 0.3 GPM. If your water flow rate is less than 
this level, your unit will not activate. Increase the flow rate. 

Water heater is not heating at all (water is flowing 
but  the  unit  is  not  heating  at  all  -  the  outgoing  water 
temperature is the same as my cold water supply) 
The digital display DOES light up. 

Internal part failure. 

Please call us for technical assistance. 

Water heater is heating but the water 
temperature is not hot enough. 

User temperature setting too low. 

Turn up the temperature setting on the unit. 

Flow rate is too high. 

Depending on your incoming water temperature and the 
power output of your model, your water flow rate may 
exceed the physical heating capacity of your water heater. 
Reduce the flow rate by installing an Eemax Flow Restrictor. 
Use the chart in section 6 to find out which flow restrictor 
works best for your particular model.  

Crossed wires. 

If it’s a new installation, have your electrician double check 
the wiring. Is possible that the wiring is incorrect. 

Voltage less than 240 volts. 

The heating elements on your water heater are design for 
240 volts. When use with a lower voltage, they produce less 
heating power. You may need to upgrade to a larger model.  

Mixing too much cold water. 

You do not need to mix as much cold water with your 
tankless water heater compared to when you use a 
conventional water heater. You may also have an anti-scald 
feature on your faucet that is mixing cold water. These 
types of faucets can usually be adjusted to reduce the 
amount of cold water mixed.  

The water temperature at my faucet is less than the 
temperature setting of my water heater. 

Voltage less than 240 volts. 

The computer chips in your tankless water heater are 
programmed with the expectation that your incoming line 
voltage is 240 volts. If you have less than 240 volts, it may 
affect the reading on your water heater’s digital display and 
cause it to read slightly higher than the actual output 
temperature. To compensate for this, increase the setting 
on your water heater if you need / want hotter water. 

Anti-Scald pressure/balancing valve or 
tempering valve. 

Your faucet may have an anti-scald feature or a tempering 
valve  that  automatically  mixes  cold  water  even  when  you 
turn your control lever or handle to full hot. These devices 
are  usually  adjustable  so  you  can  turn  off  the  cold  mix 
completely.  You  can  compensate  for  this  by  increasing  the 
setting on your water heater if you need/want hotter water. 

Thermal loss due to long pipe run 

As the hot water from the heater runs through the hot 
water delivery system to you faucet, some heat will be lost 
especially if it has long distance to travel or the pipes are 
cold. This is normal. You can compensate for this by 
increasing the setting on your water if you need/want 
hotter water. 

Summary of Contents for PR008240

Page 1: ...aker box SERIOUS BODILY INJURY OR DEATH COULD OCCUR IF YOU IGNORE THIS WARNING THIS PRODUCT SHOULD BE INSTALLED BY A QUALIFIED ELECTRICIAN OR PLUMBER IN ACCORDANCE WITH ALL NATIONAL STATE PROVINCIAL AND LOCAL ELECTRICAL PLUMBING CODES PLEASE READ THESE INSTRUCTIONS THOROUGHLY AND COMPLETELY PRIOR TO INSTALLATION USE FAILURE TO DO SO COULD CAUSE PROPERTY DAMAGE SERIOUS INJURY OR DEATH This manual s...

Page 2: ......

Page 3: ...e any questions please contact us directly at Eemax Inc 400CaptainNevilleDrive Waterbury CT06705 Toll Free 1 800 543 6163 or 203 267 7890 Fax 203 267 7975 info eemaxinc com CONTENTS 1 BEFORE INSTALLATION 2 SELECTING A LOCATION TO INSTALL 3 MOUNTING YOUR WATER HEATER 4 PLUMBING INSTALLATION 5 ELECTRICAL INSTALLATION 6 SIZING GUIDE 7 GENERAL OPERATING INSTRUCTIONS 8 MAINTENANCE 9 TROUBLE SHOOTING GU...

Page 4: ...rical boxes or junctions If you plan to install your water heater on a second floor or in a heated attic space make sure that you follow all code requirements for such installations as required for your area We recommend that you install a drip pan connected to a safe drain below the water heater to avoid property damage in the unlikely event of a leak Alternatively you can install an active water...

Page 5: ...ons UL Standard 499 does NOT require that a pressure relief valve be used However a T P valve may be required to meet installation codes in your area If one is required install the pressure relief valve in accordance with local codes and ensure that it operates correctly and that air is purged from the valve prior to installing the water heater When connecting to Flex or High Temperature CPVC pipe...

Page 6: ...Model PR024240 and PR027240 require 3 sets of wires and ground seewiringdiagram Model PR036240 requires 4 sets of wires and ground seewiringdiagram Pleaseseerequiredwiregaugeonthenextpage Eachsetofwiresmustbeconnectedtoitsownindividualdoublepolebreaker InstallationInstructions STEP1 Takeeachwirepairandconnectthem toonebreaker seewiringdiagram Makesurethateachbreakeris connectedwithoneblackwireando...

Page 7: ... AMPS REQUIRED BREAKERS 1 x 40 AMP 1 x 50 AMP 1 X 60 AMP 2 X 40 AMP 3 x 40 AMP 3 X 40 AMP 4 X 40 AMP REQUIRED WIRE GAUGE 1 x 8 AWG 1 X 6 AWG 1 X 6 AWG 2 X 8 AWG 3 x 8 AWG 3 X 8 AWG 4 X 8 AWG Circuit Breaker 1 L1 L1 PR018240 requires 2 sets of breakers and wires PR024240 PR027240 require 3 sets of breakers and wires PR036240 requires 4 sets of breakers and wires PR008240 PR011240 PR013240 require 1...

Page 8: ...heater and limit the maximum volume coming out of your unit to a specified flow rate to prevent the exit temperature from becoming too cool To learn more about flow restrictors or find out how to purchase one for your tankless water heater visit us online at Eemax com or contact us at 1 800 543 6163 Steps for Choosing a Flow Restrictor 1 Find your model in the chart on the left 2 Choose the column...

Page 9: ... risk of a water leak we recommend the following maintenance You should inspect the connections on the inlet and outlet of the water heater at least on an annual basis for any signs of damage or failure Any signs of damage cracks leakage or weakness should be addressed Take care not to over tighten the connections Serious internal damage to your water heater can occur if you over tighten the water...

Page 10: ...ossible that the wiring is incorrect Voltage less than 240 volts The heating elements on your water heater are design for 240 volts When use with a lower voltage they produce less heating power You may need to upgrade to a larger model Mixing too much cold water You do not need to mix as much cold water with your tankless water heater compared to when you use a conventional water heater You may al...

Page 11: ...change the temperature set point exposes electrical shock and burn hazards which can cause INJURY or DEATH Adjustment should only be done by a licensed plumber or electrician PR008240 PR011240 PR013240 PR018240 PR024240 PR027240 PR036240 1 Hot Water Outlet 4 Temperature Set Point Display 6 Wire Connection 2 Cold Water Inlet Remove Cover to Access 7 Brass Compression Nut 3 Celsius Fahrenheit Conver...

Page 12: ...Eemax Inc 400CaptainNevilleDrive Waterbury CT06705 Toll Free 1 800 543 6163 or 203 267 7890 Fax 203 267 7975 info eemaxinc com ...

Reviews: