DE285 HD Caption Decoder/VANC Monitor
section. To expand the module, click the downwards arrow at the top
right hand corner.
5.4.
ANC Trigger
The ANC Trigger tab allows you to create triggers made up of two parts:
the ANC data of interest, and the behavior you would like to observe.
The data type is selected using the DID/SDID value, and the trigger
can be set on behaviors such as Present, Absent, Change, Data Change
and line number. Setting triggers is a useful way to monitor incoming
ANC data to check the frequency of events such as missing data. Us-
ing the web interface, triggers can be chosen and then monitored in a
live–update pop-up window that is tied to your browser session, mak-
ing the ANC analysis tool ideal for watching until an event occurs. To
22
Copyright ©2009-2011 EEG Enterprises, Inc.