As an extension lead, only use the version specified by the manufacturer or one of a higher quality.
When using an extension lead, check the minimum cross-sections of the cable:
Cable length
Cross section
< 16 A
< 25 A
up to 20 m
1,5 mm
2
2,5 mm
2
20 to 50 m
2,5 mm
2
4,0 mm
2
Only use the appliance if it is in undamaged condition. Never use the vacuum cleaner without a filter, or if the
filter is damaged.
When dust removers are used, the rate at which air is exchanged in the room must be adequate if the
exhaust air from the vacuum cleaner is blown into the room (please observe regulations valid in your
country).
Before starting work, the operating staff must be informed on
–
use of the vacuum cleaner
–
risks associated with the material to be picked up
–
safe disposal of the picked up material
Operation
Switch position
Function
I
On
0
Off
Auto-On/Off
Picking up liquids
Before liquids are picked up, always remove the filter bag. Check that the float works properly. For
this purpose, remove the filter and check the float located in the filter holder for ease of movement by
swinging / moving the upper section of the vacuum cleaner. If foam develops or liquid emerges, stop
work immediately and empty the dirt tank.
Cleaning the filter element
If suction performance drops:
1. Switching on the vacuum cleaner.
2. Close the nozzles or suction hose opening with the palm of your hand.
3. Press the button to start filter cleaning for at least three times for two seconds each. The resulting
stream of air removes attached dust from the slats of the filter elements.
4. If the suction power is too low after filter cleaning: replace filter.
E
Blower function
The cleaner has a blower function to clean inaccessible places or to dry the surface of wet items.
Do not direct the air into rooms in an uncontrolled manner. When using the blower function, always
use a clean hose. Stirred-up dust can be hazardous to health. Do not use the blower function in closed
rooms.
F
Connecting electrical appliances
Use the socket on the vacuum cleaner for the purpose defined in the operating instructions only.
Before plugging an appliance into the appliance socket:
1. Switch off the vacuum cleaner.
2. Switch off the appliance to be connected.
CAUTION! Follow the operating instructions and safety instructions for appliances connected to the
power tool socket.
Summary of Contents for SS 1401 L
Page 2: ...2 Eibenstock SS 1401 L A 1 1 2 3 5 5 4 7 6 8...
Page 3: ...3 Eibenstock SS 1401 L B 3 3 4 8 8 7 2 5 6 11 10 1 9...
Page 4: ...4 Eibenstock SS 1401 L B...
Page 5: ...5 Eibenstock SS 1401 L C 3 3 4 2 1 5 7 7 6 8 8 9...
Page 6: ...6 Eibenstock SS 1401 L D 4 3x 3 2 1...
Page 7: ...7 Eibenstock SS 1401 L E 1 3 2...
Page 8: ...8 Eibenstock SS 1401 L F 1 2 2 3 4 5 7 8 6...
Page 9: ...9 Eibenstock SS 1401 L G 2 3 3 4 9 8 11 11 10 1 5 6 7...
Page 10: ...10 Eibenstock SS 1401 L 3 3 4 9 9 8 2 1 5 6 7 6 7 7 5 G...
Page 11: ...11 Eibenstock SS 1401 L 4 H...
Page 52: ...D GB F E I NL DK PL RUS GR TR 52 Eibenstock SS 1401 L A 1 3 L B...
Page 57: ...D GB F E I NL DK PL RUS GR TR 57 Eibenstock SS 1401 L 1 mg m L L B...
Page 67: ......
Page 68: ...Elektrowerkzeuge GmbH Eibenstock Auersbergstra e 10 D 08309 Eibenstock 107413224 2015 05 01...