MaxLoader User’s Guide
86
Enabling #4 socket to be master socket
If you want to choose the master socket in 4
th
location in 8 sockets, select the
serial number for 4
th
socket among 8 sequential serial numbers. i.e the 4
th
socket
serial number is P8-0057.
USB option / Good LED off on socket open
This option enables the LED light to not blink after finishing an operation.
So, user can recognize the empty socket as not being effective for any operation.
USB option / Enable “START ALL” button
This option enables any of the START button in multi-site programmer to be a
start button for all others. So, customers don’t need to press individual button as
an auto programming mode. Customers who want to operate a separate
operation for individual Start Button key must un-checked this option.