6.2 Operational modes
The pump can be controlled by:
▪
Manual control mode – with the buttons on the user interface panel.
▪
Parallel control mode – through the 15-way D-type logic interface connector
located on the rear of the pump.
▪
Serial control mode – through the 15-way D-type logic interface connector located
on the rear of the pump.
▪
Auto-run.
6.2.1 Manual control mode
Refer to
Figure: Interface control panel
for the pump control functions.
Table 11
Manual control mode
Operation
Button
Status
Apply power
Mains power
The pump will remain off (factory default). The power
indicator will illuminate.
Start the pump Start button
The pump will accelerate up to full running speed.
The run indicator will flash while the pump acceler-
ates. The run indicator will remain on when the pump
reaches full speed.
Select and de-
select the
standby speed
Standby mode
select button
When engaged, the standby indicator will illuminate
and the pump will run at the standby speed setting.
The pump is set by default at 70% of full speed.
Increase or de-
crease the
pump speed
when in stand-
by mode
Standby speed
increase but-
ton
The pump speed will increase.
The increase standby indicator will remain illuminated
when the pump reaches a maximum of 100% of full
speed.
Standby speed
decrease but-
ton
The pump speed will decrease.
The decrease standby indicator will remain illuminated
when the pump reaches a minimum of 50% of full
speed.
Select and de-
select the Au-
to-run func-
tion
Start or stop
button (>8 sec)
When engaged, the auto-run indicator will illuminate.
The pump will restart automatically after the power
has been restored.
Start and stop
Use the buttons (
Figure: Interface control pane
) to start and stop the pump.