© Edwards Limited 2007. All rights reserved.
Page 7
Edwards and the Edwards logo are trademarks of Edwards Limited.
Introduction
A419-00-880 Issue F
Table 1 - LEDs on the EPX pumps
LEDs/button items
Reference data
Power LED (
This green LED indicates that mains power is supplied to the EPX pump.
Run LED (
, item 3)
This green LED is lit when the EPX pump has started and is operating.
This LED will flash when the pump is operating in idle mode.
Warning LED (
, item 4)
Operational with EPX-N series of pumps only. Amber LED will illuminate
in a ‘Low Flow’ condition.
Alarm LED (
, item 5)
This red LED is lit when the EPX pump has been automatically shut
down because a pump protection sensor has operated (Refer to
), or because the inverter drive has failed.
Table 2 - Connections
Connection items
Reference data
Cooling-water inlet and outlet
(
, items 4 and 9)
Use these to connect your cooling-water supply and return pipelines to
the EPX pump: refer to
Electrical supply cable
(
Use this to connect your external electrical supply to the EPX pump:
refer to
, item 5)
Use this to connect your control equipment to the EPX pump, to allow
you to control the operation of the pump: refer to
.
Protective Earth (ground) stud
(
Use this to earth (ground) the EPX pump: refer to