![Edwards B756-51-991 Instruction Manual Download Page 23](http://html1.mh-extra.com/html/edwards/b756-51-991/b756-51-991_instruction-manual_2366091023.webp)
© Edwards Limited 2013. All rights reserved.
Page 19
Edwards and the Edwards logo are trademarks of Edwards Limited.
STORAGE AND DISPOSAL
B756-50-880 Issue C
6
STORAGE AND DISPOSAL
6.1
Storage
Use the following procedure to store the pump.
1. Remove the pump from the system as described in
2. Place the pump in its packing materials. For fastest pump-down when the pump is put back into service, seal the
pump inside a plastic bag together with a suitable desiccant.
3. Store the pump in cool, dry conditions until required for use. When required, prepare and install the pump as
described in
.
4. Keep the pump upright at all times to prevent the drainage of oil from the bearing reservoir.
5. Avoid long-term storage if possible. When long-term storage is necessary, the pump should be set up and run for
at least eight hours every six months.
6.2
Disposal
Dispose of the EXT70/70/200H Turbomolecular Pump and any components and accessories safely in accordance with
all local and national safety and environmental requirements.
Note that the pump chamber is treated with Alocrom 1000, which is a chromate conversion coating with a thickness
of < 1 micron. The total weight of the coating on the chamber is approximately 20 mg.
Particular care must be taken with any components which have been contaminated with dangerous process
substances.
Take appropriate action to avoid inhalation of any particulates that may be present in the pump.
Do not incinerate the pump. The pump contains phenolic and fluorosilicone materials that can decompose to very
dangerous substances when heated to high temperatures.
WARNING
In the unlikely event of a failure of the pump rotor, carbon fibre dust may be generated. In this
event, use appropriate personal protective equipment when handling and disposing of the pump,
and ensure that all pump inlets and outlets are capped off before disposal.