4. Installation
4.1 Safety
WARNING:
Ensure that the installation technician is familiar with the safety procedures which
relate to the pump oil and the products handled by the pumping system.
WARNING:
If a hydrocarbon oil is used in this pump, do not use the pump to process oxygen in
concentrations greater than 25% in volume. If the oxygen concentration is greater
than 25%, there is a risk of fire or explosion in the oil-box of the pump
WARNING:
Do not use the pumps to pump hazardous substances.
WARNING:
Obey the safety instructions listed below and take note of appropriate precautions.
Failure to do so can cause injury to people and damage to equipment. Prevent any
part of the human body from coming into contact with the vacuum.
Ensure that the pump is suitable for your application. If there is any doubt as to the
suitability of the pump for your application, refer our guidelines on vacuum pump and
vacuum system safety (see the Associated Publication at the end of the contents list at
the front of this manual), or contact us for advice.
A suitably trained and supervised technician must install the pump. Obey the safety
instructions listed below when installing the pump, especially when connecting the
pump into an existing system. Details of specific safety precautions are given at the
appropriate point in the instructions.
▪
Wear the appropriate safety clothing when coming into contact with contaminated
components is anticipated. Dismantle and clean contaminated components inside
a fume cupboard.
▪
Vent and purge the vacuum system before starting installation work.
▪
Take suitable precautions to avoid the inhalation of oil mist and excessive skin
contact with pump-oil, as prolonged exposure can be harmful.
▪
Disconnect the other components in the pumping system from the electrical
supply so that they cannot be operated accidentally.
▪
Safely route any electrical cables so that they cannot accidentally trip people.
4.2 System design
Consider the following points when designing the pumping system:
Page 17
A37132880_F - Installation
Summary of Contents for A37104902
Page 43: ...Page 41 A37132880_F Service...