Edvotek EdvoCycler Quick Manual Download Page 6

EDVOTEK®  •  1.800.EDVOTEK (1.800.338.6835)  •  FAX:  (301) 340.0582

www.edvotek.com  •  [email protected]

6

LOAD SAVED PROGRAM, continued

3.

Load tubes in block.  If all spaces will be used, it may be necessary to “nest”
tubes (place tubes aligned with one another and facing the same direc-
tion).  See Figure 1.   Close lid.

4.

Press the RUN button.  The lid starts to preheat or the cycling will begin im-
mediately.

5.

When the cycling steps begin, you can monitor the progress on the
screen display.  The flashing arrow indicates the current status.  The
bottom row (Cycles) shows current cycle to the left and the total # of
cycles to the right.

6.

To end the cycling at any time: Press the escape button and scroll
with the up or down button, enter 

YES

 to stop the experiment.

MODIFY SAVED PROGRAM

Use this function to modify or to make an adjustment to an existing pro-
gram.

1.

Scroll to 

MODIFY SAVED PROGRAM

 and press enter.

2.

Scroll up or down to the desired program and press enter.

3.

Scroll to the setting you wish to change and press enter.  When the item disappears, enter the
new parameter.

4.

Scroll to another setting you wish to modify.  After you are satisfied with the changes to the
program, press the escape button and the changes will be saved.  Time is entered as seconds
(i.e. 30 seconds is displayed as 0030, 2 minutes is displayed as 0120).

5.

To run the modified program, scroll to 

LOAD SAVED PROGRAM

 and follow the directions running

a saved program.

CREATE NEW PROGRAM

Note - if an incorrect entry is made at any time during 

CREATE NEW PROGRAM

, simply scroll up or

down to the wrong entry and press enter.  When the item disappears, enter the correct parameter.

1.

Scroll to 

CREATE NEW PROGRAM

 and press enter.

2.

Press the enter button and then enter the new program number.

3.

If an initial denaturation is not desired, scroll down to 

Denaturation

 (see below for entering PCR

cycles).

4.

If an initial denaturation is desired, press the enter button and enter the 

Initial Denaturation

temperature.  Next, press the enter button again and enter the 

Initial Denaturation

 time (i.e. for

3 min., enter the time as 0180).

continued

Warning !

The heated lid

will get very hot –

use extreme

caution to avoid

getting burned

Figure 1

Summary of Contents for EdvoCycler

Page 1: ...hase of the EdvoCycler Thermalcycler TABLE OF CONTENTS Introduction 2 Warnings 2 Operator Safety 2 Installation 2 After Use 2 User Maintenance 3 Guarantee 3 Contact Information 3 EdvoCycler Quick Guide 4 Getting Started 5 Load Saved Program 5 Modify Saved Program 6 Create New Program 6 Delete Saved Program 7 Temp Hold Params 7 Run Saved Program 8 Pause or Escape 8 ...

Page 2: ... procedures If the equipment is used in a manner not specified by EDVOTEK the protection provided by the equip ment to the user may be impaired All EDVOTEK units have been designed to conform to interna tional safety requirements and are fitted with an over temperature cutout The cutout is preset to protect the unit If a safety problem should be encountered switch off at the mains socket and remov...

Page 3: ... you may need to return the unit for repair The fuse is located in the back of the unit in the AC adapter Guarantee The unit is guaranteed against any defect in material or workmanship for two years Please fill out the warranty card as soon as possible to ensure proper warranty coverage The warranty period is from the date of purchase and within this period all defective parts will be replaced fre...

Page 4: ...gram and goes to hold WARNING Running the unit for long periods of time at high or low temperatures will shorten the lifespan of the unit Change values by pressing ENTER and keying in numerical values To modify the tempera ture time and number of cycles scroll to value to be changed press ENTER Using keys 0 9 punch in desired value NOTE need to keep same number of digits so if 45 sec enter 0045 On...

Page 5: ...DIFY SAVED PROGRAM CREATE NEW PROGRAM DELETE SAVED PROGRAM RUN PROGRAM LOAD SAVED PROGRAM Use this function if you are running an EDVOTEK kit The programs for most EDVOTEK PCR kits are pre loaded on the EdvoCycler and ready to run Simply follow ED VOTEK instructions for preparing DNA samples for PCR and place tubes in the EdvoCycler The block holds only 0 2 ml PCR tubes if PCR sample is prepared i...

Page 6: ...nge and press enter When the item disappears enter the new parameter 4 Scroll to another setting you wish to modify After you are satisfied with the changes to the program press the escape button and the changes will be saved Time is entered as seconds i e 30 seconds is displayed as 0030 2 minutes is displayed as 0120 5 To run the modified program scroll to LOAD SAVED PROGRAM and follow the direct...

Page 7: ... at the Cycles default Enter the number of cycles for the PCR cycling steps The number to the right is the total number of cycles and the number to the left will display as the current cycle in progress DELETE SAVED PROGRAM The EdvoCycler can hold 20 saved programs From time to time it may be necessary to delete old programs to make room for new programs Remember once a program is deleted it canno...

Page 8: ...temporarily hold a cycle at a certain point USE EXTREME CAUTION WHEN OPENING THE LID AND REMOVING SAMPLES FROM THE BLOCK THE HEATED LID AND BLOCK WILL BE VERY HOT 2 When ready to return to the program replace samples to the block close the lid and push the RUN button 3 To stop the program while it is running press the escape button Press the up or down button to YES and press enter to abort the pr...

Reviews: